Message type: E = Error
Message class: BTP_DL -
Message number: 089
Message text: Combining of '&1' with '&2' is possible
Combining compatibility of solutions is maintained with so-called
configuration sets. A configuration set specifies if solutions can be
combined into one single step in the project execution plan. Then, for
all the combined solutions in a step one single conversion package can
be created. Configuration sets are delivered by SAP with the portfolio
content of SAP LT and are not visible on the user interface.
Solutions '&V1&' and '&V2&' can be combined because configuration set '
&V3&' (&V4&) defines the compatibility of these solutions.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
BTP_DL089
- Combining of '&1' with '&2' is possible ?The SAP error message BTP_DL089 indicates that there is an issue with combining two different data types or structures in a way that is not allowed. This error typically arises in scenarios involving data processing, such as when working with Business Technology Platform (BTP) or when using SAP Data Intelligence.
Cause: The error message BTP_DL089 is triggered when there is an attempt to combine two incompatible data types or structures. This could happen in various contexts, such as: Mismatched data types in a data flow or transformation. Incorrectly configured data models or schemas. Attempting to join or merge datasets that do not have compatible structures.
Solution: To resolve the BTP_DL089 error, you can take the following steps: Check Data Types: Review the data types of the fields or structures you are trying to combine. Ensure that they are compatible. For example, if you are trying to combine a string with a number, you may need to convert one
Get instant SAP help. Sign up for our Free Essentials Plan.
BTP_DL088
Combining of '&1' with '&2' is not possible
What causes this issue? Combining compatibility of solutions is maintained with so-called configuration sets. A configuration set specifies if soluti...
BTP_DL087
Check step &1 for combining with step &2
Two steps (a source and a target step) in the project execution plan can be combined if each solution of the source step is compatible for combining ...
BTP_DL090
Exactly one RFC destination must be flagged for PIFD initialization
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
BTP_DL091
Solutions &1 and &2 differ in used system landscape type
What causes this issue? Each solution in the project execution plan requires a system landscape of a special type. The system landscape types require...
Click on this link to search all SAP messages.