Message type: E = Error
Message class: BRAIN -
Message number: 562
Message text: Inconsistent formula group: Element &1 is in the wrong structure
This formula group is malformed, as one of its inverse formulas &V1&
(type &V3&) is not in the same structure as the carrier for the formula
group.
The query is malformed and cannot be generated.
Adjust the query definition so that the situation described above no
longer persists.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
BRAIN562
- Inconsistent formula group: Element &1 is in the wrong structure ?The SAP error message BRAIN562 indicates that there is an inconsistency in a formula group, specifically that an element is in the wrong structure. This typically occurs in the context of SAP BW (Business Warehouse) or SAP BI (Business Intelligence) when working with queries, formulas, or data models.
Cause: Incorrect Formula Configuration: The formula group may have been incorrectly configured, leading to elements being placed in the wrong structure. Changes in Data Model: If there have been recent changes to the underlying data model (like InfoObjects, InfoProviders, or queries), it may lead to inconsistencies. Transport Issues: If the formula group was transported from one system to another, it might not have been properly adjusted for the target environment. Version Mismatch: There may be a mismatch between the versions of the elements used in the formula and the current version in the system.
Solution: Check Formula Configuration: Review the formula group configuration to ensure that all elements are
Get instant SAP help. Sign up for our Free Essentials Plan.
BRAIN561
Inconsistent carrier &1 of a formula group (see long text)
What causes this issue? You want to use element &V1& as the carrier of a formula group. The carrier of a formula group must be an input-ready...
BRAIN560
Inverse formulas are not permitted if the key figure is in the filter
What causes this issue? No input-ready formulas (and therefore no inverse formulas either) can be defined in a query whose key figure is defined in t...
BRAIN563
Carrier &1 of the formula group is not in the key figure structure
What causes this issue? Formula group carrier &V1& is not in the query#s key figure structure. This is not allowed.System Response The query...
BRAIN564
Input-ready formula &1 does not have any inverse formulas
What causes this issue? Formula &V1& is input ready, but no inversions have been specified for the input-ready operands. This is not allowed....