Do you have any question about this error?
Message type: E = Error
Message class: BRAIN -
Message number: 377
Message text: Variable for "Data Integrity" cannot be used
A variable is being used in the query for query property <ZK>Data
Integrity</> . Characteristic <ZK>0REQUID</> is also being used in a
selection as a free characteristic. This combination is not supported.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Adjust the query definition accordingly.
Error message extract from SAP system. Copyright SAP SE.
BRAIN377
- Variable for "Data Integrity" cannot be used ?The SAP error message BRAIN377, which states "Variable for 'Data Integrity' cannot be used," typically occurs in the context of SAP Business Warehouse (BW) or SAP BusinessObjects when there is an issue with the data integrity variable in a query or report. This error can arise due to several reasons, and understanding the cause is essential for finding a solution.
Causes of BRAIN377 Error
Variable Configuration Issues: The variable for data integrity may not be properly configured in the BW system. This could include incorrect settings or missing attributes.
Data Source Compatibility: The variable may not be compatible with the data source being used in the query. For example, if the variable is defined for a specific InfoProvider but is being used with another that does not support it.
Authorization Issues: The user may not have the necessary authorizations to access the variable or the data it is supposed to represent.
Query Design Problems: The query might be designed in a way that does not allow the use of the data integrity variable, such as incorrect filters or joins.
Data Integrity Settings: The settings for data integrity in the BW system may not be correctly defined, leading to the variable being unusable.
Solutions to BRAIN377 Error
Check Variable Configuration:
- Go to the variable settings in the BW system and ensure that the variable for data integrity is correctly configured. Verify that all necessary attributes and settings are in place.
Review Data Source:
- Ensure that the variable is being used with the correct InfoProvider. If the variable is specific to a certain InfoProvider, it should not be used with others that do not support it.
Verify Authorizations:
- Check the user’s authorizations to ensure they have the necessary permissions to access the variable and the associated data.
Examine Query Design:
- Review the query design to ensure that it is set up correctly. Look for any filters or joins that might be causing the variable to be unusable.
Adjust Data Integrity Settings:
- If applicable, review the data integrity settings in the BW system. Make sure that they are correctly defined and that the variable is set to be used as intended.
Consult Documentation:
- Refer to SAP documentation or support notes related to the specific version of BW or BusinessObjects you are using. There may be known issues or additional configuration steps required.
Testing:
- After making changes, test the query or report again to see if the error persists. It may be helpful to create a simplified version of the query to isolate the issue.
Related Information
By following these steps, you should be able to identify the cause of the BRAIN377 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
BRAIN376
The InfoProvider properties for &1 are not the same as the system default
What causes this issue? Property &V2& has been set differently to the system default. Current setting: &V4& for &V1& System d...
BRAIN375
Query contains non-cumulative key figures and other incompat. functions
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
BRAIN378
Formula element '&1 &2' cannot be input-ready
What causes this issue? A formula element can only be input ready if at least one preceding operand is input ready, and an inverse formula has been d...
BRAIN379
InfoProvider &1 inconsistent: PartProvider &2 is not actively available
What causes this issue? MultiProvider &V1& is inconsistent. It contains PartProvider &V2&. This is either not available or not active...