Message type: E = Error
Message class: BRAIN -
Message number: 232
Message text: Get data for aggregate part &1 of exactly one DTP from delta part &2
The delta pair process for InfoCubes can only succeed if there is one
DTP from the InfoCube &V3& that serves as the delta part, to the
InfoCube &V2& that serves as the aggregation part.
The MultiProvider cannot be used in this way.
Check the corresponding entries in table RSDCUBEMULTI.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
BRAIN232
- Get data for aggregate part &1 of exactly one DTP from delta part &2 ?The SAP error message BRAIN232 typically occurs in the context of data extraction and loading processes, particularly when working with Data Transfer Processes (DTP) in SAP BW (Business Warehouse). This error indicates that there is an issue with retrieving data for a specific aggregate part from a delta load.
Cause: The error message BRAIN232 can be caused by several factors, including: Inconsistent Delta Data: The delta data for the DTP might be inconsistent or incomplete, leading to issues when trying to retrieve data for the specified aggregate. Incorrect DTP Configuration: The DTP might not be configured correctly, which can lead to problems in fetching the required data. Data Source Issues: There may be issues with the underlying data source, such as missing or corrupted data. Aggregate Issues: The aggregate itself may not be properly defined or may have been changed, leading to discrepancies in the data retrieval process. Process Chain Issues: If the DTP is part of
Get instant SAP help. Sign up for our Free Essentials Plan.
BRAIN231
For &1, parameter &2 can only have references to &3 (current value = &4)
What causes this issue? Delta pair class &V1& permits class &V3& only as import parameter &V2&. However, &V4& was tra...
BRAIN230
Could not buffer query structures. Buffer too small
What causes this issue? To improve the runtime, the structures needed by the OLAP engine are stored in the shared memory. This query requires &V1...
BRAIN233
Aggregate part &1 must not be a real-time InfoCube
What causes this issue? InfoCube &V1& is entered as the aggregate pair of a delta pair. This is not possible for real-time InfoCubes.System R...
BRAIN234
Property 'All Basic Key Figures Input Ready' is not permitted for &1
What causes this issue? The InfoProvider is an aggregation level or contains the aggregation level &V1& as an InfoProvider contained in the M...
Click on this link to search all SAP messages.