Do you have any question about this error?
Message type: E = Error
Message class: /BOFU/FDT_EXP_BO_RET -
Message number: 207
Message text: Structure expected for result data &1; syst. will generate new structure
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/BOFU/FDT_EXP_BO_RET207
- Structure expected for result data &1; syst. will generate new structure ?The SAP error message
/BOFU/FDT_EXP_BO_RET207 Structure expected for result data &1; syst. will generate new structure
typically occurs in the context of SAP's Business Object Framework (BOF) or when working with the Flexible Data Model (FDT). This error indicates that the system expected a specific structure for the result data but did not find it, leading the system to generate a new structure instead.Cause:
- Missing Structure Definition: The expected structure for the result data is not defined in the system. This can happen if the structure was deleted or not properly configured.
- Inconsistent Data Model: There may be inconsistencies in the data model or the configuration of the business object that leads to the system not recognizing the expected structure.
- Version Mismatch: If there are changes in the data model or the business object definitions, and the system is not updated accordingly, it may lead to this error.
- Transport Issues: If the structure was transported from one system to another (e.g., from development to production) and the transport did not include all necessary components, this error may occur.
Solution:
- Check Structure Definition: Verify that the expected structure is defined in the system. You can do this by checking the relevant configuration settings in the FDT or BOF.
- Recreate Structure: If the structure is missing, you may need to recreate it manually or ensure that it is properly defined in the system.
- Consistency Check: Perform a consistency check on the data model and business object definitions to identify any discrepancies.
- Transport Validation: If the issue arose after a transport, check the transport logs to ensure that all necessary components were included and correctly transported.
- System Update: Ensure that your system is up to date with the latest patches and updates, as this may resolve any underlying issues related to the error.
- Consult Documentation: Refer to SAP documentation or notes related to the specific version of the FDT or BOF you are using for any known issues or additional troubleshooting steps.
Related Information:
If the problem persists after trying the above solutions, it may be beneficial to reach out to SAP support for further assistance.
Get instant SAP help. Start your 7-day free trial now.
/BOFU/FDT_EXP_BO_RET206
Line type &2 in result data &1 not suitable; syst. will create new struct
What causes this issue? The line type in the result data object is not suitable for the field map.System Response The system will automatically crea...
/BOFU/FDT_EXP_BO_RET205
Generation of result data not possible; make field selections
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/BOFU/FDT_EXP_BO_RET208
Enter structure name
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/BOFU/FDT_EXP_BO_RET209
Enter table name
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.