Do you have any question about this error?
Message type: E = Error
Message class: /BOBF/CONF -
Message number: 181
Message text: Transient nodes must not be set as separately lockable
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/BOBF/CONF181
- Transient nodes must not be set as separately lockable ?The SAP error message
/BOBF/CONF181
indicates that there is an issue with the configuration of transient nodes in the Business Object Processing Framework (BOPF). Specifically, it states that transient nodes must not be set as separately lockable.Cause:
In BOPF, transient nodes are used to hold temporary data that does not need to be persisted in the database. These nodes are typically used for calculations or intermediate results. The error occurs when a transient node is incorrectly configured to be separately lockable, which is not allowed because transient data does not have a persistent state that can be locked.
Solution:
To resolve this error, you need to check the configuration of the transient node in your BOPF model. Here are the steps to fix the issue:
Access the BOPF Model: Go to the BOPF modeling environment in your SAP system (transaction code
BOPF
or through the relevant development tools).Identify the Transient Node: Locate the transient node that is causing the error. You can usually find this in the node definitions of your BOPF business object.
Check Node Properties: Open the properties of the transient node and look for the setting related to "Separately Lockable".
Modify the Configuration: Ensure that the "Separately Lockable" option is not checked for the transient node. This setting should be disabled for any transient nodes.
Save and Activate: After making the necessary changes, save your configuration and activate the BOPF model.
Test the Changes: After activation, test the functionality that was previously causing the error to ensure that the issue has been resolved.
Related Information:
By following these steps, you should be able to resolve the /BOBF/CONF181
error and ensure that your BOPF model is correctly configured.
Get instant SAP help. Start your 7-day free trial now.
/BOBF/CONF180
Transient nodes must not be set as separately loadable
What causes this issue? Transient nodes must not be set as separately loadable/ lockable.Error message extract from SAP system. Copyright SAP SE. ...
/BOBF/CONF179
Generated Mapper Class is out of date: Regeneration necessary
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/BOBF/CONF182
Conversion rule &1 is mandatory for mapping of attribute &2 in &3 &4
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/BOBF/CONF183
Conversion rule &1 is superfluous for mapping of attribute &2 in &3 &4
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.