Do you have any question about this error?
Message type: E = Error
Message class: BDT_CONSISTENCY_CHCK - Messages for BDT_CHECK
Message number: 049
Message text: Screen field &1 for screen table &2 is not stored in BDT table TBZ3R
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
BDT_CONSISTENCY_CHCK049
- Screen field &1 for screen table &2 is not stored in BDT table TBZ3R ?The SAP error message BDT_CONSISTENCY_CHCK049 indicates that there is a consistency check failure related to the Business Data Toolset (BDT). Specifically, it means that a screen field (denoted as
&1
) for a particular screen table (denoted as&2
) is not stored in the BDT tableTBZ3R
. This can occur during the configuration of BDT applications when there is a mismatch between the screen fields defined in the application and those that are expected to be stored in the BDT tables.Cause:
- Missing Field Definition: The screen field that is referenced in the error message has not been defined in the BDT table
TBZ3R
. This could happen if the field was added to the screen but not properly configured in the BDT.- Inconsistent Configuration: There may be inconsistencies in the configuration of the BDT application, such as changes made to the screen layout or field definitions that were not reflected in the BDT tables.
- Transport Issues: If the configuration was transported from one system to another, there may have been issues during the transport that caused the field definitions to be incomplete.
Solution:
Check Field Definition: Verify that the screen field mentioned in the error message is correctly defined in the BDT configuration. You can do this by:
- Navigating to the BDT configuration transaction (e.g.,
BDT
orSPRO
).- Checking the screen table and ensuring that the field is listed in the BDT table
TBZ3R
.Add Missing Field: If the field is missing, you will need to add it to the BDT table
TBZ3R
. This can typically be done through the BDT configuration interface:
- Go to the relevant screen table configuration.
- Add the missing field and ensure that it is properly configured.
Consistency Check: After making changes, run a consistency check to ensure that all fields are correctly defined and that there are no further inconsistencies.
Transport Management: If the issue arose due to a transport, ensure that all relevant objects were included in the transport request and that the transport was successful. You may need to re-transport the configuration if necessary.
Documentation and Support: If you are unable to resolve the issue, consult SAP documentation or reach out to SAP support for further assistance.
Related Information:
TBZ3R
for screen field definitions.SPRO
for configuration and BDT
for BDT-specific settings.By following these steps, you should be able to identify and resolve the cause of the error message BDT_CONSISTENCY_CHCK049.
Get instant SAP help. Start your 7-day free trial now.
BDT_CONSISTENCY_CHCK048
DB table field &1 for table &2 is not defined in DDIC
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
BDT_CONSISTENCY_CHCK047
Change document object &1 is not defined in DDIC
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
BDT_CONSISTENCY_CHCK050
Assignment of view &1 for object part &2 is obsolete; use the data sets
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
BDT_CONSISTENCY_CHCK051
Application &1 is not active
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.