Do you have any question about this error?
Message type: E = Error
Message class: ARCH_ANA - Table Analysis
Message number: 101
Message text: Table &1 not active
For this table it is not possible to create new analyses, analysis
variants, etc., nor is it possible to display existing analyses.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
ARCH_ANA101
- Table &1 not active ?The SAP error message ARCH_ANA101 indicates that a specific table (denoted as
&1
in the message) is not active in the context of the SAP Archive Management system. This error typically arises when you attempt to perform operations related to archiving or accessing archived data, but the required table is not in an active state.Cause:
- Table Not Activated: The most common cause is that the table has not been activated in the system. This can happen if the table is newly created or if it has been deactivated for some reason.
- Missing Configuration: The archiving object related to the table may not be properly configured or activated in the system.
- Transport Issues: If the table was transported from another system, it might not have been activated in the target system.
- Database Issues: There could be underlying database issues that prevent the table from being recognized as active.
Solution:
Activate the Table:
- Go to the Data Dictionary (transaction code SE11).
- Enter the name of the table that is causing the error.
- Check if the table is active. If it is not, activate it by clicking on the "Activate" button.
Check Archiving Object:
- Use transaction code SARA to check the archiving object related to the table.
- Ensure that the archiving object is properly configured and activated.
Transport Request:
- If the table was transported, ensure that the transport request was completed successfully and that all necessary objects were included.
Database Consistency:
- Check for any database inconsistencies. You may need to run database consistency checks or consult your database administrator.
Consult Documentation:
- Review SAP documentation or notes related to the specific archiving object or table for any additional steps or considerations.
Contact SAP Support:
- If the issue persists after trying the above solutions, consider reaching out to SAP support for further assistance.
Related Information:
Transaction Codes:
SAP Notes: Check for any relevant SAP Notes that might address this specific error or provide additional troubleshooting steps.
System Logs: Review system logs (transaction SM21) for any related error messages that might provide more context about the issue.
By following these steps, you should be able to resolve the ARCH_ANA101 error and ensure that the necessary tables are active for archiving operations.
Get instant SAP help. Start your 7-day free trial now.
ARCH_ANA100
* -------------------- Function group ARCH_ANA ----------------------- *
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
ARCH_ANA031
The field &1 cannot be used as a dynamic subfield
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
ARCH_ANA102
Table field &1 not contained in table &2 (analysis variant &3)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
ARCH_ANA103
Table &1: Error during generation
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.