Message type: E = Error
Message class: AJ - Billing program
Message number: 513
Message text: Not possible to take JT effect into account for thermal gas billing 03
You have selected thermal gas billing 03. Here, the register already
takes all components required for calculating the volume correction
factor into account.
It is therefore not necessary to take into account the change in
temperature due to the Joule-Thomson effect, since the temperature is
not used in any other calculations.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
AJ513
- Not possible to take JT effect into account for thermal gas billing 03 ?The SAP error message AJ513, which states "Not possible to take JT effect into account for thermal gas billing 03," typically occurs in the context of gas billing processes, particularly when dealing with Joint Tariff (JT) effects in thermal gas billing scenarios. This error can arise due to various reasons, and understanding the cause is essential for finding a solution. Causes: Missing Configuration: The system may not be properly configured to handle Joint Tariff effects for the specific billing type (in this case, thermal gas billing). Data Inconsistencies: There may be inconsistencies or missing data in the master data or transaction data related to the billing process. Incorrect Billing Type: The billing type used may not support the Joint Tariff effects, or it may not be correctly set up in the system. Period Issues: The billing period may not be valid for applying Joint Tariff effects, or there may be issues with the billing period
Get instant SAP help. Sign up for our Free Essentials Plan.
AJ512
Cannot maintain MeasPrPror/GasPrDeterm/GasPrCorr for thermal gas bill. &1
What causes this issue? In thermal gas billing &v1&, the register already takes the pressure into account. Therefore, you only have to enter ...
AJ511
Volume correction factor is missing for register for period &2 to &3
What causes this issue? The volume correction factor for device/register &V1& is to be determined using the <LS>Reg. VCF</> proce...
AJ514
Joule-Thompson effect is not taken into account for special procedures
What causes this issue? The Joule-Thomson effect cannot be taken into account for special procedures <LS>Reg. rel. ZZ</>, <LS>Reg. ...
AJ515
In gas procedure &1, &3 is missing from VCF procedure &2
What causes this issue? The gas procedure you have entered references a volume correction factor (VCF) procedure with a fixed VCF. You maintain the f...