Do you have any question about this error?
Message type: E = Error
Message class: AH - IS-U billing (master data)
Message number: 857
Message text: Device &1 reg. &2 period &3 - &4: no conversion factor due to gas date
No entry for the device, register and period you have specified was
found that can be used to determine the conversion factor.
It is likely that the gas date and the normal meter reading date are
too far apart. In this particular case, the month to which the program
refers back (which is derived from the gas month of previous billing)
is too far in front of the from-date of the earliest time slice of the
current billing.
Important: If the weighted average of the conversion factor is
calculated by means of degree day weighting, the gas month must not be
more than one month before the meter reading date.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Check the gas date setting, in particular in scheduling. You can find
the gas date in scheduling once the meter reading results have been
entered.
Billings and orders that have already been processed with an
impermissible gas month may need to be reversed and processed again.
If neither of the above are the case, the problem may be due to an
internal error. If this is the case, contact SAP.
Error message extract from SAP system. Copyright SAP SE.
AH857
- Device &1 reg. &2 period &3 - &4: no conversion factor due to gas date ?The SAP error message AH857 typically relates to issues in the context of gas measurement and billing within the SAP IS-U (Industry Solution for Utilities) module. This error indicates that there is a problem with the conversion factor for gas measurement due to the gas date specified in the transaction.
Cause:
The error message AH857 can occur due to several reasons:
Missing Conversion Factors: The conversion factors for the specified gas date are not maintained in the system. This can happen if the conversion factors have not been set up for the relevant period or if they have been incorrectly configured.
Incorrect Gas Date: The gas date provided in the transaction may not correspond to a valid period for which conversion factors are defined.
Data Inconsistencies: There may be inconsistencies in the master data related to the gas measurement points, such as missing or incorrect entries in the relevant tables.
Configuration Issues: There may be issues in the configuration of the gas measurement and billing processes, leading to the inability to retrieve the necessary conversion factors.
Solution:
To resolve the AH857 error, you can take the following steps:
Check Conversion Factors:
- Navigate to the relevant configuration settings in SAP to verify that conversion factors for the specified gas date are maintained.
- Ensure that the conversion factors are correctly defined for the relevant periods.
Verify Gas Date:
- Check the gas date being used in the transaction. Ensure that it falls within a valid range for which conversion factors are available.
Review Master Data:
- Inspect the master data for the gas measurement points to ensure that all necessary information is complete and accurate.
- Look for any missing entries or inconsistencies that could affect the conversion factor retrieval.
Consult Documentation:
- Refer to SAP documentation or help resources for specific guidance on maintaining conversion factors and handling gas measurement data.
Contact Support:
- If the issue persists after checking the above points, consider reaching out to your SAP support team or consulting with an SAP expert who specializes in IS-U for further assistance.
Related Information:
By following these steps, you should be able to identify and resolve the underlying issues causing the AH857 error in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
AH856
Update to deletion variant: overwriting of values is not permitted
What causes this issue? You are updating an amount in schema step &v1& with variant &v2& to schema step &v3& with variant &am...
AH855
Device &1 reg. &2 period &3 - &4: conversion factor cannot be determined
What causes this issue? Internal error: No entry was found in internal table UL_MVCF-EXTRACT_IEGAS for the specified interval and the specfied device...
AH858
Enter replacement VCF procedure for register relationship ZZ only
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
AH859
Replacement vol. corr. factor proc. is required for reg. relationship ZZ
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.