Do you have any question about this error?
Message type: E = Error
Message class: AH - IS-U billing (master data)
Message number: 753
Message text: Number of demand peaks is 0 for register operand &1
You must specify a value in the <DS:DE.PEAK_NO>No. of peaks</> field
for a <DS:DE.REG_OPER>register operand</> from the DEMAND operand
category.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
AH753
- Number of demand peaks is 0 for register operand &1 ?The SAP error message AH753, which states "Number of demand peaks is 0 for register operand &1," typically occurs in the context of SAP IS-U (Industry Solution for Utilities) when dealing with meter reading and demand calculation processes. This error indicates that the system is unable to find any demand peaks for the specified register operand, which is essential for calculating demand values.
Cause:
- No Meter Readings: The most common cause is that there are no meter readings available for the specified period or for the specific register operand.
- Incorrect Configuration: The configuration for the register operand may not be set up correctly, leading to the system not being able to identify any demand peaks.
- Data Gaps: There may be gaps in the data that prevent the system from calculating demand peaks.
- Incorrect Time Interval: The time interval for which the demand peaks are being calculated may not align with the available data.
Solution:
- Check Meter Readings: Verify that there are valid meter readings for the specified register operand. Ensure that readings are recorded for the relevant time period.
- Review Configuration: Check the configuration settings for the register operand in the SAP system. Ensure that it is set up correctly to capture demand peaks.
- Data Consistency: Ensure that there are no gaps in the data. If there are missing readings, consider entering them or adjusting the time period for the demand calculation.
- Adjust Time Interval: If the time interval for demand calculation is incorrect, adjust it to match the available data.
- Reprocess Demand Calculation: After making the necessary adjustments, reprocess the demand calculation to see if the error persists.
Related Information:
EL31
(for meter reading) or EL32
(for demand calculation) to check and manage meter readings and demand calculations.If the issue persists after following these steps, it may be beneficial to consult with your SAP support team or a technical consultant who specializes in SAP IS-U for further assistance.
Get instant SAP help. Start your 7-day free trial now.
AH752
Operand &1: control fields for demand are filled
What causes this issue? The following fields must be left blank for operand &V1&: <DS:DE.PEAK_NO>No. of peaks</>, <DS:DE.LEIST...
AH751
Specify a schema that contains a period-end billing rate
What causes this issue? You have established a period-end billing in the rate category. However, the specified schema does not contain a period-end b...
AH754
Register operands only possible for operand categories QUANT or DEMAND
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
AH755
Maximum line item &1 not equal to &2 (FM &3)
What causes this issue? It has been determined in function module &v3& that the IERCHZ table has &v1& line items. This contradicts th...
Click on this link to search all SAP messages.