Do you have any question about this error?
Message type: E = Error
Message class: AH - IS-U billing (master data)
Message number: 662
Message text: Calorific value procedure &1 is not active
A calorific value procedure that is no longer active cannot be used.
This means that a procedure indicated as inactive is not accepted when
you create or change a gas procedure.
Error message
If this procedure is to be used, cancel the 'inactive' indicator in the
calorific value procedure.
Error message extract from SAP system. Copyright SAP SE.
AH662
- Calorific value procedure &1 is not active ?The SAP error message AH662, which states "Calorific value procedure &1 is not active," typically occurs in the context of the SAP Environment, Health, and Safety (EHS) module or when dealing with the management of materials that have calorific values, such as fuels or other energy-related products.
Cause:
The error indicates that the specific calorific value procedure referenced by the placeholder
&1
is not active in the system. This can happen for several reasons:
- The procedure has not been defined or configured in the system.
- The procedure may have been deactivated or not properly assigned to the relevant material or process.
- There may be a configuration issue in the settings related to calorific value procedures.
Solution:
To resolve this error, you can follow these steps:
Check Procedure Activation:
- Go to the configuration settings for calorific value procedures in SAP. This is usually found in the customizing settings under the relevant module (e.g., EHS).
- Verify if the procedure identified by
&1
is defined and active.Activate the Procedure:
- If the procedure is not active, you may need to activate it. This typically involves setting the procedure to an active status in the configuration.
Assign the Procedure:
- Ensure that the calorific value procedure is correctly assigned to the relevant materials or processes. This may involve checking material master records or other relevant configuration settings.
Review Documentation:
- Consult the SAP documentation or help resources for specific instructions on how to manage calorific value procedures. This can provide insights into the correct configuration steps.
Consult with SAP Support:
- If you are unable to resolve the issue through the above steps, consider reaching out to SAP support or your internal SAP team for further assistance. They may have additional insights or access to system logs that can help diagnose the issue.
Related Information:
SPRO
to access the configuration settings or MM02
to check material master data.By following these steps, you should be able to identify the cause of the error and implement a solution to activate the necessary calorific value procedure in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
AH661
Volume correction factor procedure &1 is not active
What causes this issue? A volume correction factor procedure that is no longer active cannot be used. This means that a procedure indicated as inacti...
AH660
Manual credit memo/backbilling &1 cannot be reversed
What causes this issue? A manual credit memo/backbilling with no link to invoicing/accounts receivable and/or payable cannot be reversed with the bil...
AH663
Key date is missing for month-based billing
What causes this issue? Installation &V1& contains <DS:DE.TARIFTYP>rate category</> &V2& until the end of the billing per...
AH664
Enter a price level for rental prices
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.