How To Fix AH576 - Dev. &1 reg. &2 per. &3 - &4: temp. missing for det. of gas law dev.fact.


SAP Error Message - Details

  • Message type: E = Error

  • Message class: AH - IS-U billing (master data)

  • Message number: 576

  • Message text: Dev. &1 reg. &2 per. &3 - &4: temp. missing for det. of gas law dev.fact.

  • Show details Hide details
  • What causes this issue?

    Internal error:
    You have specified a device/register for which the gas law deviation
    factor is to be determined for each pressure and temperature. The
    temperature could not be determined for the period you have specified.

    System Response

    An error has occurred.

    How to fix this error?

    Check whether a temperature area or a fixed temperature key is assigned
    to your device/register.
    If not, complete the missing data and repeat this transaction.
    If this data already exists, an internal error has occurred. In this
    case, contact SAP.

    Error message extract from SAP system. Copyright SAP SE.


Smart SAP Assistant

  • What is the cause and solution for SAP error message AH576 - Dev. &1 reg. &2 per. &3 - &4: temp. missing for det. of gas law dev.fact. ?

    The SAP error message AH576 typically relates to issues in the calculation of gas law development factors in the context of oil and gas production or reservoir engineering. This error indicates that the temperature data required for the determination of the gas law development factor is missing for a specific development area or well.

    Cause:

    1. Missing Temperature Data: The primary cause of this error is that the temperature data for the specified development area (Dev. &1), registration (reg. &2), and period (per. &3) is not available in the system.
    2. Data Entry Issues: There may have been an oversight in entering the required temperature data into the system.
    3. Configuration Issues: The system may not be properly configured to retrieve or calculate the necessary temperature data for the gas law calculations.

    Solution:

    1. Check Data Entry: Verify that the temperature data for the specified development area, registration, and period has been entered correctly in the system. If it is missing, you will need to input the correct temperature data.
    2. Review Configuration: Ensure that the system is configured correctly to access and utilize the temperature data for gas law calculations. This may involve checking the settings in the relevant SAP modules.
    3. Consult Documentation: Refer to SAP documentation or help resources for specific instructions on how to enter or correct temperature data related to gas law calculations.
    4. Contact Support: If the issue persists after checking the data and configuration, consider reaching out to SAP support or your internal IT team for further assistance.

    Related Information:

    • Gas Law Development Factor: This factor is used in the calculation of gas volumes and is essential for accurate reservoir management and production forecasting.
    • SAP Modules: This error may be encountered in modules related to oil and gas management, such as SAP PM (Plant Maintenance), SAP PS (Project System), or SAP IS-Oil.
    • Data Management: Regular audits of data entries and configurations can help prevent such errors from occurring in the future.

    By addressing the missing temperature data and ensuring proper system configuration, you should be able to resolve the AH576 error and proceed with your calculations.

    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.