Message type: E = Error
Message class: AH - IS-U billing (master data)
Message number: 576
Message text: Dev. &1 reg. &2 per. &3 - &4: temp. missing for det. of gas law dev.fact.
Internal error:
You have specified a device/register for which the gas law deviation
factor is to be determined for each pressure and temperature. The
temperature could not be determined for the period you have specified.
An error has occurred.
Check whether a temperature area or a fixed temperature key is assigned
to your device/register.
If not, complete the missing data and repeat this transaction.
If this data already exists, an internal error has occurred. In this
case, contact SAP.
Error message extract from SAP system. Copyright SAP SE.
AH576
- Dev. &1 reg. &2 per. &3 - &4: temp. missing for det. of gas law dev.fact. ?The SAP error message AH576 typically relates to issues in the calculation of gas law development factors in the context of oil and gas production or reservoir engineering. This error indicates that the temperature data required for the determination of the gas law development factor is missing for a specific development area or well.
Cause: Missing Temperature Data: The primary cause of this error is that the temperature data for the specified development area (Dev. &1), registration (reg. &2), and period (per. &3) is not available in the system. Data Entry Issues: There may have been an oversight in entering the required temperature data into the system.
Configuration Issues: The system may not be properly configured to retrieve or calculate the necessary temperature data for the gas law calculations.
Solution: Check Data Entry: Verify that the temperature data for the specified development area, registration, and period has been entered correctly in the system. If it is
Get instant SAP help. Sign up for our Free Essentials Plan.
AH575
Dev.&1 reg.&2 per.&3-&4: meas.press. missing for det. of GasLawDev.factor
What causes this issue? Internal error: You have specified a device/register for which the gas law deviation factor is to be determined for each pres...
AH574
Dev.&1 reg.&2 VCF proc.&3: not poss.to det. gas law dev.fact.- miss.temp.
What causes this issue? You have specified a device/register for which the gas law deviation factor is to be determined from pressure and temperature...
AH577
Meas. pressure &1 +/- sign &2 temperature &3 not in table &4
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
AH578
Values for operand &1 must not be deleted
What causes this issue? You have attempted to delete the values for operand &v1&. However, this is not possible because values exist for the ...