Do you have any question about this error?
Message type: E = Error
Message class: AD - Data Dictionary application messages
Message number: 375
Message text: Table type changed (delete the table dynpro)
The table type was changed from POOL/CLUSTER to INTTAB. Existing
data was lost in the process.
The table screen for the old POOL/CLUSTER type table must be deleted.
Data in the database must also be deleted.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Use the 'Delete data' function to delete this data.
INCLUDE ADIC-DB-UTILITIES
Use Screen Painter to delete the table screen.
Error message extract from SAP system. Copyright SAP SE.
AD375
- Table type changed (delete the table dynpro) ?The SAP error message AD375, which states "Table type changed (delete the table dynpro)," typically occurs when there is a mismatch between the data dictionary definition of a table and the associated screen (dynpro) that is used to display or manipulate that table's data. This can happen when the structure of a table is modified (for example, fields are added, removed, or changed) but the corresponding screen has not been updated to reflect these changes.
Cause:
- Table Structure Change: The underlying database table structure has been modified (e.g., fields added or removed).
- Screen Not Updated: The screen (dynpro) that is associated with the table has not been updated to reflect these changes.
- Inconsistent Data Dictionary: There may be inconsistencies between the data dictionary and the screen definitions.
Solution:
To resolve the AD375 error, follow these steps:
Identify the Affected Table: Determine which table is causing the error. This information is usually provided in the error message or can be found in the transaction where the error occurred.
Check Table Structure: Use transaction SE11 (Data Dictionary) to check the current structure of the table. Look for any recent changes that may have been made.
Update the Screen:
- Use transaction SE80 (Object Navigator) or SE41 (Menu Painter) to locate the screen (dynpro) associated with the table.
- Update the screen to ensure it matches the current structure of the table. This may involve adding or removing fields, adjusting field properties, etc.
Delete the Old Dynpro: If the screen is no longer needed or if it is outdated, you may need to delete the old dynpro. This can be done in SE80 or SE41.
Activate Changes: After making the necessary changes, ensure that you activate both the table and the screen to apply the updates.
Test the Changes: After making the updates, test the transaction or program that was causing the error to ensure that the issue has been resolved.
Related Information:
If the problem persists after following these steps, it may be beneficial to consult with a technical SAP consultant or developer who can provide further assistance.
Get instant SAP help. Start your 7-day free trial now.
AD374
Create a database table
What causes this issue? The activated VIEW table is new. Please create a corresponding database view.System Response The system issues an error mess...
AD373
Fields deleted; update the DB table/data
What causes this issue? Fields at the end of the table have been deleted. TRANSP-type tables can only be activated if the database table has been adj...
AD376
Table type changed; data may have been invalidated
What causes this issue? The table type was changed from POOL/CLUSTER to TRANSP. For performance reasons, it was not possible to check automatically f...
AD377
Key format changed; update the data
What causes this issue? Activation of the table has been cancelled. The table key has changed. The table of type POOL/CLUSTER contains data. Before a...
Click on this link to search all SAP messages.