Message type: E = Error
Message class: ACMDT_OBJSTATUS - ACM: Messages for the Object-Status of Designtime-Objects
Message number: 275
Message text: Runtime header entry is orphaned (has no related designtime rule)
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
ACMDT_OBJSTATUS275
- Runtime header entry is orphaned (has no related designtime rule) ?The SAP error message ACMDT_OBJSTATUS275 indicates that there is a runtime header entry that is orphaned, meaning it does not have a corresponding design-time rule. This typically occurs in the context of SAP applications that utilize the Application Configuration Management (ACM) framework, where design-time rules are expected to be linked to runtime entries.
Cause:
- Missing Design-Time Rule: The most common cause of this error is that a design-time rule that should correspond to the runtime entry has been deleted or is missing.
- Data Inconsistency: There may be inconsistencies in the database where the runtime entries are not properly linked to their design-time counterparts.
- Transport Issues: If changes were transported from one system to another (e.g., from development to production), it’s possible that the transport did not include all necessary objects, leading to orphaned entries.
- Manual Deletion: Manual deletions or modifications in the configuration can lead to orphaned entries if the corresponding design-time rules are not updated accordingly.
Solution:
- Check Design-Time Rules: Verify that the design-time rules exist and are correctly configured. If they are missing, you may need to recreate them.
- Recreate Orphaned Entries: If you identify that certain runtime entries are orphaned, you may need to recreate them or link them to the appropriate design-time rules.
- Database Consistency Check: Perform a consistency check on the database to identify and resolve any inconsistencies between runtime and design-time objects.
- Transport Review: If the issue arose after a transport, review the transport logs to ensure that all necessary objects were included and correctly imported.
- SAP Notes: Check the SAP Support Portal for any relevant SAP Notes that may address this specific error or provide patches or updates that resolve the issue.
- Consult Documentation: Review the official SAP documentation for ACM and related components to ensure that all configurations are set up correctly.
Related Information:
By following these steps, you should be able to identify the root cause of the ACMDT_OBJSTATUS275 error and implement a suitable solution.
Get instant SAP help. Start your 7-day free trial now.
ACMDT_OBJSTATUS274
ACMTST DCL has no ABAP artifacts
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
ACMDT_OBJSTATUS273
Non-productive DCL has no active version
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
ACMDT_OBJSTATUS276
CTE of type: BASEV has no corresponding CTE of type: AUTHV/CONDV
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
ACMDT_OBJSTATUS277
CTE of type: HEADV has no corresponding runtime header
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.