Do you have any question about this error?
Message type: E = Error
Message class: 67_RFC - Message Class for RFC Modules
Message number: 205
Message text: Collateral type &1, category &2 and transfer structure &3 do not match
The structure you have transferred for a collateral type does not
belong to the collateral type or to the collateral category.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Transfer another collateral type or fill another structure.
Error message extract from SAP system. Copyright SAP SE.
67_RFC205
- Collateral type &1, category &2 and transfer structure &3 do not match ?The SAP error message "67_RFC205 Collateral type &1, category &2 and transfer structure &3 do not match" typically occurs in the context of SAP's Financial Services or Treasury modules, particularly when dealing with collateral management or related financial transactions. This error indicates a mismatch between the specified collateral type, category, and transfer structure in a remote function call (RFC) or during data transfer.
Cause:
- Mismatch in Configuration: The collateral type, category, and transfer structure may not be correctly configured in the system. Each collateral type is associated with specific categories and transfer structures, and if these do not align, the error will occur.
- Data Entry Errors: Incorrect data entry when specifying the collateral type, category, or transfer structure can lead to this error.
- Changes in Configuration: If there have been recent changes to the configuration of collateral types or transfer structures, it may lead to inconsistencies.
- Incompatible Versions: If the RFC is being called from a different system or version that does not support the specified configurations, this error can arise.
Solution:
Check Configuration: Verify the configuration settings for collateral types, categories, and transfer structures in the SAP system. Ensure that they are correctly defined and aligned.
- Use transaction codes like
SPRO
to access the configuration settings.- Navigate to the relevant sections for collateral management and check the definitions.
Validate Data Entry: Review the data being passed in the RFC call. Ensure that the collateral type, category, and transfer structure are correctly specified and match the definitions in the system.
Review Recent Changes: If there have been recent changes to the configuration, review those changes to ensure they have been implemented correctly and that they do not conflict with existing settings.
Consult Documentation: Refer to SAP documentation or help resources for guidance on the specific collateral types and their associated categories and transfer structures.
Testing: If possible, perform tests with different combinations of collateral types and categories to identify the specific mismatch.
Contact SAP Support: If the issue persists after checking configurations and data, consider reaching out to SAP support for further assistance. They may provide insights based on the specific version and configuration of your SAP system.
Related Information:
SPRO
(Customizing), SE37
(Function Module), and SE80
(Object Navigator) for debugging and configuration.By following these steps, you should be able to identify and resolve the cause of the error message.
Get instant SAP help. Start your 7-day free trial now.
67_RFC204
The &3 must be transferred for collateral type &1 and collateral cat. &2
What causes this issue? No collateral has been transferred or an incorrect collateral has been transferred for the pre-set collateral type.System Res...
67_RFC203
Collateral type does not exist in the SAP system - no receation for &1
What causes this issue? A pre-set collateral type could not be found in check table TD01. The system issues an error message and will not allow you t...
67_RFC206
No structure &3 has been transferred for collateral type &1 and cat. &2
What causes this issue? Expiry data has been transferred that has not been recorded in the system because it does not belong to the collateral. This ...
67_RFC207
Table TD01 for collateral types is not maintained in the SAP system
What causes this issue? You want to check the validity of a pre-set collateral type in the Customizing table TD01. There are no entries in this table...
Click on this link to search all SAP messages.