Do you have any question about this error?
Message type: E = Error
Message class: 53 - Incentive Wages Data
Message number: 380
Message text: No link maintained to target system &2
The distribution model does not include a link to required target
system(s) &V2&.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Check that the correct target system has been selected, or inform your
system administrator.
Check the distribution model. Has target system &V2& been entered? Has
object &V3& been entered with method &V4& for the link from &V1& to
&V2&?
Error message extract from SAP system. Copyright SAP SE.
53380
- No link maintained to target system &2 ?The SAP error message "53380 No link maintained to target system &2" typically indicates that there is an issue with the connection or link between the source system and the target system in an SAP landscape. This error can occur in various scenarios, such as during data transfer, system replication, or when trying to access a remote system.
Cause:
- Missing RFC Destination: The most common cause is that the Remote Function Call (RFC) destination to the target system is not defined or is incorrectly configured.
- Authorization Issues: The user may not have the necessary authorizations to access the target system.
- Network Issues: There may be network connectivity issues preventing the source system from reaching the target system.
- System Configuration: The target system may not be properly configured to accept connections from the source system.
- Transport Layer Issues: If this error occurs during a transport operation, it may indicate that the transport layer is not set up correctly.
Solution:
Check RFC Destination:
- Go to transaction
SM59
in the source system.- Verify that the RFC destination for the target system exists and is correctly configured.
- Test the connection to ensure it is working properly.
Review Authorizations:
- Ensure that the user has the necessary authorizations to access the target system.
- Check roles and profiles assigned to the user.
Network Connectivity:
- Verify that there are no network issues preventing communication between the two systems.
- Check firewall settings and ensure that the necessary ports are open.
System Configuration:
- Ensure that the target system is configured to accept connections from the source system.
- Check the instance profile and ensure that the necessary parameters are set.
Transport Layer Configuration:
- If the error occurs during a transport operation, check the transport layer settings in transaction
STMS
.- Ensure that the transport routes are correctly defined.
Check Logs:
- Review system logs (transaction
SM21
) and developer traces (transactionST22
) for any additional error messages that may provide more context.Related Information:
By following these steps, you should be able to identify and resolve the cause of the error message "53380 No link maintained to target system &2".
Get instant SAP help. Start your 7-day free trial now.
53379
No log is required for step &1
What causes this issue? Domain KKAKTIO does not include fixed value &V1.System Response The system does not write a log record.Error message ext...
53378
&1 blocks with time diffences were transferred to Logistics
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
53381
No target system could be found
What causes this issue? None of the logical systems in the selection conditions is entered in the distribution model as a target system for object &a...
53400
Error during export/import
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.