Message type: E = Error
Message class: 0T - WBO Configuration Editor / SE06
Message number: 090
Message text: Test of group &1 not possible, since connection to &2 failed
You cannot test the target group &V1&, since the clients in the SAP
system &V2& could not be read. You need to set up an RFC call for the
adjustment with the existing clients in the affected SAP systems.
The target groups are ready to be maintained.
Make sure that the required SAP systems are available before the first
import.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
0T090
- Test of group &1 not possible, since connection to &2 failed ?The SAP error message 0T090 indicates that a test of a group (usually a user group or a configuration group) could not be performed because the connection to a specified system or server failed. This error typically arises in scenarios involving system connections, such as when testing RFC (Remote Function Call) connections or when trying to access a specific system for configuration or data retrieval. Causes: Network Issues: There may be network connectivity problems between the SAP system and the target system. Incorrect Configuration: The connection parameters (like hostname, port, or credentials) for the target system may be incorrectly configured. Target System Down: The target system may be down or not reachable due to maintenance or other issues. Firewall Restrictions: Firewalls or security settings may be blocking the connection to the target system. Authorization Issues: The user may not have the necessary authorizations to access the target system. Solutions: Check Network Connectivity: Use tools like ping or traceroute to
Get instant SAP help. Sign up for our Free Essentials Plan.
0T089
Target group &1 unknown
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
0T088
Target group must begin and end with '/'
What causes this issue? The syntax of the transport target is incorrect.System Response The input is rejected.How to fix this error? The transport ...
0T091
Specify a transport target name
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
0T092
Client '&2' not found in the system &1
What causes this issue? The client &V2& was not found in the SAP system &V1&. Possible errors: There was an error when reading the cl...
Click on this link to search all SAP messages.