Do you have any question about this error?
Message type: E = Error
Message class: 0K - Messages for "General List Modules"
Message number: 510
Message text: No field catalog entry exists for referred units field &
A currency/measurement unit field which has no field catalog entry is
referred to in the field catalog.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
0K510
- No field catalog entry exists for referred units field & ?The SAP error message 0K510 ("No field catalog entry exists for referred units field &") typically occurs in the context of reporting or data extraction, particularly when dealing with the characteristics of a data source or when trying to display certain fields in a report or query.
Cause:
The error indicates that the system is unable to find a corresponding field catalog entry for the specified unit field. This can happen due to several reasons:
- Missing Field Catalog Entry: The field catalog for the report or query does not include the specified unit field.
- Incorrect Configuration: The configuration of the data source or the report may not be set up correctly, leading to the absence of the required field.
- Data Source Issues: The data source being used may not have been properly defined or may not include the necessary fields.
- Authorization Issues: Sometimes, the user may not have the necessary authorizations to access certain fields.
Solution:
To resolve the error, you can take the following steps:
Check Field Catalog:
- Verify that the field catalog for the report or query includes the required unit field. You may need to add the field to the catalog if it is missing.
Review Data Source Configuration:
- Ensure that the data source is correctly configured and includes all necessary fields. You may need to adjust the settings or definitions of the data source.
Update Report/Query:
- If you are using a custom report or query, check the underlying logic to ensure that it references the correct fields. You may need to modify the report to include the missing field.
Check Authorizations:
- Ensure that the user has the necessary authorizations to access the fields in question. You may need to consult with your SAP security team to verify and adjust user roles.
Consult Documentation:
- Refer to SAP documentation or help resources for specific guidance related to the report or data source you are working with.
Contact SAP Support:
- If the issue persists after trying the above steps, consider reaching out to SAP support for further assistance. They may provide insights specific to your SAP environment.
Related Information:
By following these steps, you should be able to identify the root cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
0K509
Referred units field & does not exist in the output table &
What causes this issue? A currency/measurement unit field which is not in the output table is referred to in the field catalog.System Response The s...
0K508
No status set in callback routine &
What causes this issue? A callback routine for setting an application-defined status was specified but no status is set in this routine.System Respon...
0K511
& & of field & & is unknown
What causes this issue? An unknown output table name was assigned to an interface parameter.System Response The system issues an error message and w...
0K512
Reference field & of reference structure & is not in ABAP Dictionary
What causes this issue? The field referred to was not found in the Data Dictionary.System Response The system issues an error message and will not a...
Click on this link to search all SAP messages.