Message type: E = Error
Message class: RSDD_ZA - Messages from TREX Aggregate Area
Message number: 153
Message text: Prüfung der Verwendung des Shared Memories im BW Accelerator
This check examines the usage and percentage usage of the shared memory
in your SAP NetWeaver BI Accelerator. It also checks whether the
capacity of the shared memory on all blades is set equally. The amount
of remaining free memory is specified as a percentage of the total
memory. If the amount of free memory is less than 30% of the total
memory, the check message is given a warning status (<ZK>yellow</>). If
this amount is less than 25%, the check message is given an error status
(<ZK>red</>).
Das System gibt eine Fehlermeldung aus und erlaubt Ihnen nicht, mit dieser Transaktion fortzufahren, bis der Fehler behoben ist.
The system tries to solve the problem automatically by executing one of
various actions; for example, by deleting objects that are no longer
used from the memory. If the system cannot solve the problem
automatically, it prompts you to increase the shared memory if the
shared memory requires more capacity.
If the check identifies that a different amount of memory is allocated
to the shared memory on each of the blades, you are prompted to adjust
the amount of memory allocated to the shared memory on each blade so
that there is an equal amount on each blade.
For more information, see SAP Notes 991567 and 997772.
Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE
RSDD_ZA153
- Prüfung der Verwendung des Shared Memories im BW Accelerator ?Get instant SAP help. Start your 7-day free trial now.
RSDD_ZA152
Ein Neustart der Server-Landschaft des BW Accelerators wurde durchgeführt
Was verursacht dieses Problem? This check indicates that the server landscape for BW Accelerator has been restarted. For more information, see the ...
RSDD_ZA151
Interner Fehler beim Ausführen der Prüfung &1
Was verursacht dieses Problem? An internal error occurred during execution of a check (&V1&). The cause of the problem is unknown. More inf...
RSDD_ZA154
Der Alertserver wurde gestoppt und runtergefahren
Was verursacht dieses Problem? The check lets you know that the alert server has been stopped and shut down.Systemantwort Das System gibt eine Fe...
RSDD_ZA155
Prüfung auf Checks, die durch den MemWatcher deaktiviert wurden
Was verursacht dieses Problem? The system checks whether MemWatcher is activated and which functions it executes. Depending on the results, certain...
Klicken Sie auf diesen Link, um alle SAP-Meldungen durchsuchen.