Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: QS - QM: Master data
Message number: 081
Message text: Klassenmerkmal und Stammprüfmerkmal passen nicht zusammen
You want to assign a class characteristic to the master inspection
characteristic after the master inspection characteristic was created.
The two characteristics, however, are not compatible.
The prerequisites that must be fulfilled in order to assign a class
characteristic depends on whether the class characteristic is of the
data type "<ZH>NUM</>" or "<ZH>CHAR</>."
If the general characteristic is of the data type "<ZH>NUM</>," the
following conditions must be fulfilled:
The master inspection characteristic must be <ZH>quantitative</>.
The two characteristics must have identical units of measurement, if a
unit is assigned to the class characteristic.
The control indicator for the upper specification limit and the control
indicator for the lower specification limit must be set in the master
inspection characteristic.
The interval limits for the class characteristic must be maintained as
follows:
Das System gibt eine Fehlermeldung aus und erlaubt Ihnen nicht, mit dieser Transaktion fortzufahren, bis der Fehler behoben ist.
<ZH>Master insp. characteristic</> <ZH>Class characteristicEnter a class characteristic that is compatible with the master
inspection characteristic.
Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE
QS081
- Klassenmerkmal und Stammprüfmerkmal passen nicht zusammen ?Get instant SAP help. Sign up for our Free Essentials Plan.
QS080
Im Stammprüfmerkmal werden Daten vorbelegt
Was verursacht dieses Problem? You want to create a link to a class characteristic. To do this, certain data has to be changed in the master inspec...
QS079
Verweis auf Klassenmerkmal wird nicht übernommen
Was verursacht dieses Problem? You wanted to create a master inspection characteristic using a copy model. However, the characteristic used as the ...
QS082
Stammprüfmerkmal als "Unvollständige Kopiervorlage" nicht möglich
Was verursacht dieses Problem? You want to use a master inspection characteristic that has been changed without history as an incomplete copy model...
QS083
Geben Sie den Toleranzschlüssel ein
Selbsterklärende Nachricht Da SAP der Meinung ist, dass diese spezielle Fehlermeldung 'selbsterklärend' ist, wurden keine weiteren Informationen geg...
Klicken Sie auf diesen Link, um alle SAP-Meldungen durchsuchen.