Message type: E = Error
Message class: QA - QM : Inspection lots
Message number: 072
Message text: Status der Probe &1 verhindert Rücknahme der Stichprobenberechnung
If you carry out the function "Cancel sample calculation" this affects
all the material samples in the inspection lot; they are given the
status "Deletion flag active".
However, you cannot set the deletion flag for sample &V1&
because of its current status.
You cannot cancel the inspection sample calculation.
Check the status of the material sample &V1&, and make changes if
required.
Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE
Get instant SAP help. Sign up for our Free Essentials Plan.
QA071 Sie haben für das Prüflos bereits Rückmeldungen erfaßt
Was verursacht dieses Problem? You have already made a completion confirmation for the QM order that is assigned to the inspection lot.Systemantwor...
QA070 Fehler beim Sichern der Materialbelegdaten zum Prüflos
Was verursacht dieses Problem? A fatal error occurred when the material was posted for the inspection lot.Systemantwort The data cannot be saved....
QA073 Sperre der Probe &1 verhindert Rücknahme der Stichprobenberechnung
Was verursacht dieses Problem? If you execute the function <LS>Cancel sample calculation</>, this affects all material samples of the i...
QA074 Ein Systemfehler verhindert die Rücknahme der Stichprobenberechnung
Was verursacht dieses Problem? If you execute the function <LS>Cancel sample calculation</>, this affects all material samples of the i...