Do you have any question about this error?
Message type: E = Error
Message class: PYC_CONF_WB -
Message number: 070
Message text: Semant.Wert & wird für Definition von Filtervalidierungsregel abgelehnt.
This validation rule is used as filter by other validation rules to
suppress their alerts. You see this message because the semantic value
for semantic category <AB>PYD_CKFLTR </>for the filter validation rule
is not the validation rule ID.
<ZH>Background</>
One validation rule X can be used as filter to suppress the check
results of other validation rules (Y and Z for example). As a result, if
an alert detected by Y and Z is already raised by validation rule X, the
same alert will not be shown by Y and Z.
Prior to Configuration Workbench, this is implemented in Customizing
activity Define Check Types (under Customizing for <LS>Payroll ->
Payroll International -> Payroll Control Center -> Payroll Control
Center Configuration Simplification</>.)
For validation rule X, which is used as filter, assign the semantic
category <AB>PYD_CKFLTR </>and any pairing semantic value (for example,
ABCD).
For validation rules Y and Z, which use validation rule X as filter,
assign the semantic category <AB>PYD_NEED </>and the same pairing value
(ABCD in this case).
RESET N1
In Configuration Workbench, this is implemented by configuring alert
dependencies for validation rules:
Enable validation rule X as a filter by selecting the checkbox <LS>This
validation rule can be used by other validation rules to suppress raised
alerts </>on the <LS>Alert Dependencies </>tab page.
Add validation rule X in the alert dependencies of validation rules Y
and Z on the <LS>Alert Dependencies </>tab page.
With Configuration Workbench, you no longer need to enter a pairing
value, but the validation rule ID is used automatically as the semantic
value for <AB>PYD_CKFLTR</> if the validation rule is used as a filter.
This custom-paring-value implementation in Customizing activity is now
deprecated with the introduction of Configuration Workbench. With
Configuration Workbench, the pairing value is the ID of the filter
validation rule.
The <LS>Consistency Check for Existing Objects with Configuration
Workbench </>(<AB>PYC_SUPPORT_CWB_CONS_CHECK</>) report can update the
configuration by doing the following:
RESET N1
For filter validation rule X, change from <AB>PYD_CKFLTR = ABCD </>to
<AB>PYD_CKFLTR = ID of filter validation rule X</>.
Find all validation rules with <AB>PYD_NEED = ABCD</>. In this example,
they are validation rules Y and Z.
Check whether there are other validation rules (W, for example) that
provides a filter by using the same pairing key ABCD: <AB>PYD_CKFLTR =
ABCD</>.
If yes, for validation rules Y and Z, change from <AB>PYD_NEED = ABCD
</>to <AB>PYD_NEED = ID of filter validation rule X</>.
If no other filter validation rules use the same pairing value
<AB>PYD_CKFLTR = ABCD</>, then for validation rules Y and Z, change from
<AB>PYD_NEED = ABCD </>to <AB>PYD_NEED = ID of filter validation rule X
</> and delete the entry <AB>PYD_NEED = ABCD</>.
<ZH>Result</>
Validation rule X is still used as filter by relevant validation rules.
But now the pairing semantic value is the ID of the filter validation
rule X rather than a custom semantic value. This is the required logic
of Configuration Workbench.
(Recommended) If you want the report to apply the abovementioned
solution for you, choose <LS>Apply Solution </>in the application
toolbar bar on the <LS>Display All Convertible Configurations </>page of
the report.
If you want to change the configuration by yourself, you can manually
edit alert dependencies for relevant validation rules in Configuration
Workbench or edit the semantic values of relevant validation rules in
Customizing activity <LS>Define Check Types</>.
Das System gibt eine Fehlermeldung aus und erlaubt Ihnen nicht, mit dieser Transaktion fortzufahren, bis der Fehler behoben ist.
Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE
PYC_CONF_WB070
- Semant.Wert & wird für Definition von Filtervalidierungsregel abgelehnt. ?Get instant SAP help. Start your 7-day free trial now.
PYC_CONF_WB069
Semantischer Wert &1 ist für Alert-Abhängigkeit obsolet.
alerts </>on the <LS>Alert Dependencies </>tab page. Add validation rule X in the alert dependencies of validation rule Y on the &l...
PYC_CONF_WB066
Sie sind nicht berechtigt, Objekte zu bearbeiten.
Was verursacht dieses Problem? The authorization for accessing Configuration Workbench and editing objects in it is controlled by the authorization...
PYC_CONF_WB071
Land/Region &1 der Validierungsregel &2 ist mit Richtlinie inkonsistent.
the report. If you want to change the configuration by yourself, you can manually edit the country/region attribute in Configuration Workbench or in ...
PYC_CONF_WB072
Land/Region &1 des Analysediagramms &2 ist mit Analysen inkonsistent.
Was verursacht dieses Problem? The analytics chart must have the same country/region as the analytics that the analytics chart is assigned to. This...
Klicken Sie auf diesen Link, um alle SAP-Meldungen durchsuchen.