How To Fix PAK197 - Oberpaket &1 nicht erlaubt wegen unterschiedlicher zugeordneter Schalter


SAP Error Message - Details

  • Message type: E = Error

  • Message class: PAK - Package API / Package Tools

  • Message number: 197

  • Message text: Oberpaket &1 nicht erlaubt wegen unterschiedlicher zugeordneter Schalter

  • Show details Hide details
  • Was verursacht dieses Problem?

    The new superpackage &V1& cannot be assigned due to switches with
    varying assignments.
    Package &V2& is not assigned to any switch.
    Package &V1& is assigned to switch &V3&.
    If switch &V3& is deactivated, a change to the superpackage would result
    in deactivation of all switchable objects of the current package &V4& as
    well as its subpackages.
    This is a completely incompatible change that is not supported,
    particularly when transporting the package change.
    Using the transaction <DS:TRAN.SFW_BROWSER>Switch Framework Browser</>,
    you can display the switched objects. Use the search function in the
    transaction to locate the package or the switch.

    Systemantwort

    Das System gibt eine Fehlermeldung aus und erlaubt Ihnen nicht, mit dieser Transaktion fortzufahren, bis der Fehler behoben ist.

    Wie behebe ich diesen Fehler?

    If it is absolutely imperative that the superpackage assignment be
    changed, perform the following changes first before you execute this new
    assignment:
    Change switch &V3& in such a way that it references package &V4&, which
    is to be reassigned.
    If switch &V3& cannot be changed: Define a new switch that references
    package &V4&. Enter for this switch all the business functions that
    switch &V3& depends on.
    If there are no switchable objects in the package hierarchy yet, the
    change to the superpackage is non-critical and the superpackage can be
    changed by a user with structure package authorization.

    Vorgehensweise für Systemadministratoren


    Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE


Smart SAP Assistant

  • Was ist die Ursache und Lösung für den SAP Fehler PAK197 - Oberpaket &1 nicht erlaubt wegen unterschiedlicher zugeordneter Schalter ?




    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.


Zugehörige SAP-Fehlermeldungen

Klicken Sie auf die Links unten, um die folgenden verwandten Nachrichten anzuzeigen:

Klicken Sie auf diesen Link, um alle SAP-Meldungen durchsuchen.


Rating
ERPlingo simplifies finding the accurate answers to SAP message errors. I now use every week. A must have tool for anyone working with SAP! Highly recommended!
Rate 1
Kent Bettisworth
Executive SAP Consultant