Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 232
Message text: SMU: Parameter für Standarddichte und -brennwert sind nicht einheitlich.
You have maintained a unit of measure for the base density of a natural
gas in the conversion group that is maintained in the unit of measure
customizing table ( T006) with additional parameters ( temperature and
pressure values and units ). The base heating value that is maintained
in the conversion group is also maintained in that way. The values for
temperature and pressure have to be identical for both the base density
unit and the base heating value unit. Otherwise, the system issues this
error message and the calculation is halted, since inconsistent results
would be obtained.
Das System gibt eine Fehlermeldung aus und erlaubt Ihnen nicht, mit dieser Transaktion fortzufahren, bis der Fehler behoben ist.
Change the settings in the conversion group. Enter a base density unit
and a base heating value unit that have identical parameters for
metering. Alternatively, you may remove the units of measure if no
conversion is required to the parameters attached to the units, or you
remove the flag in the conversion group that activates the additional
conversion: <DS:TRAN.O580>Change conversion group settings</>
Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE
O3232
- SMU: Parameter für Standarddichte und -brennwert sind nicht einheitlich. ?Get instant SAP help. Sign up for our Free Essentials Plan.
O3231
SMU: Werte und Einheiten für Standardtemp. und druck werden ersetzt.
Was verursacht dieses Problem? In the conversion group, an indicator is set to activate additional conversion routines. The routines convert the ba...
O3230
& inakt. Vorschl.wert-Sätze werden gesichert; vor Verwendung aktivieren!
Was verursacht dieses Problem? You have maintained several default sets and saved the data. However, not all default sets have been activated . Thi...
O3233
SMU: Einheit mit der Dimension "dimensionslos" ist nicht vorhanden.
Was verursacht dieses Problem? The system tried to retrieve one unit of measure with the "dimensionless" dimension, but not one unit has ...
O3234
Falsche Dimension: Einheit mit der Dimension "dimensionslos" eingeben.
Selbsterklärende Nachricht Da SAP der Meinung ist, dass diese spezielle Fehlermeldung 'selbsterklärend' ist, wurden keine weiteren Informationen geg...