Do you have any question about this error?
Message type: E = Error
Message class: HH - (Long) text for check tool 'infcfgcheck'
Message number: 069
Message text: Bitte editieren Sie die Informix-ONCONFIG-Datei
The ONCONFIG parameter 'STACKSIZE' is set very low in your system.
As of R/3 Release 4.5A recommends a minimum setting of
64 K (for example, to prevent termination of transactions due to
complex
SQL statements (with 'FOR ALL ENTRIES' clauses). If you choose another
setting, you should avoid setting 'STACKSIZE' too high (to the maximum
value of 256K, for example) to minimize shared memory use. For more
information, see note 38307.
Das System gibt eine Fehlermeldung aus und erlaubt Ihnen nicht, mit dieser Transaktion fortzufahren, bis der Fehler behoben ist.
To change 'STACKSIZE', edit (as the user 'informix') the file
'$INFORMIXDIR/etc/$ONCONFIG'.
CAUTION: The change is only activated after the database is restarted.
Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE
HH069
- Bitte editieren Sie die Informix-ONCONFIG-Datei ?Get instant SAP help. Start your 7-day free trial now.
HH068
Bitte überprüfen Sie die 'rawdevice' Links auch manuell!
Was verursacht dieses Problem? This message is not an error! On the SINIX operating system platform, it is not possible to check whether the rawdev...
HH067
Die Anzahl der Dbspace-Chunks ist (sehr) kritisch (wg. ontape/onarchive)
Was verursacht dieses Problem? The specified dbspace consists of many chunks: Background: The Informix backup tools 'ontape' and 'on...
HH070
Bitte editieren Sie die Informix-ONCONFIG-Datei
Was verursacht dieses Problem? The ONCONFIG parameter 'DD_HASHSIZE' is set very low in your system. As of Release 4.5A, we recommend a mi...
HH071
Bitte editieren Sie die Informix-ONCONFIG-Datei
Was verursacht dieses Problem? The ONCONFIG parameter 'DD_HASHMAX' is set very low in your system. As of Release 4.5A, we recommend a min...
Klicken Sie auf diesen Link, um alle SAP-Meldungen durchsuchen.