Do you have any question about this error?
Message type: E = Error
Message class: FDT_CORE - Formula & Derivation Tool: Core
Message number: 447
Message text: Komponente &1 wurde in DDIC-Struktur &2 von Schalter &3 (&4) deaktiviert
For the current structure, the system has detected the following status:
By the time the binding has been established between the current
structure and DDIC structure &v2&, the structure component &v1& has been
available and is therefore part of the current BRFplus structure data
object.
In the meantime, switch &v3& has been turned off so that component &v1&
is no longer available in the bound DDIC structure &v3&. However, the
BRFplus structure still contains a data object corresponding to the now
unavailable component.
It is still possible to use the BRFplus structure. However, you should
check whether component &v2& is actually required for rule processing.
If you refresh the binding, the component will no longer be part of the
BRFplus structure.
Das System gibt eine Fehlermeldung aus und erlaubt Ihnen nicht, mit dieser Transaktion fortzufahren, bis der Fehler behoben ist.
If component &v2& is not required for the rule logic, refresh the
binding. If it is crucial for your application to access the
switched-off component &v1&, do one of the following:
Do not refresh the binding.
Turn switch &v3& on.
You should ensure that all BRFplus functions using structure &v2& can be
called only if switch &v3& is on. Otherwise, it could happen that
initial values are passed and processed for component &v1& by accident.
Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE
FDT_CORE447
- Komponente &1 wurde in DDIC-Struktur &2 von Schalter &3 (&4) deaktiviert ?Get instant SAP help. Start your 7-day free trial now.
FDT_CORE446
Komponente &1 der DDIC-Struktur &2 wird von Schalter &3 (&4) gesteuert
Was verursacht dieses Problem? The system has detected that in the bound DDIC structure &v2&, the availability of component &v1& is...
FDT_CORE445
Komponente &1 d DDIC-Struktur &2 n gebunden: Schalter &3 (&4) deaktiviert
Was verursacht dieses Problem? You have established a binding relationship between the current structure data object and DDIC structure &v2&...
FDT_CORE448
Data Dictionary(DDIC)-Typ &1 ist von Schalter &2 (&3) ausgeschaltet
Was verursacht dieses Problem? The system has detected that the DDIC type &v1& to which the current data object is bound is controlled by s...
FDT_CORE449
Data Dictionary(DDIC)-Typ &1 wird von Schalter &2 (&3) gesteuert
Was verursacht dieses Problem? The system has detected that the availability of data dictionary type &v1& to which the current data object ...
Klicken Sie auf diesen Link, um alle SAP-Meldungen durchsuchen.