Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now

Close

How To Fix EL106 - Gerät &1 AblDatum &2: Abweichung vom Vorablesestand > zulässiger Festwert


SAP Error Message - Details

  • Message type: E = Error

  • Message class: EL - IS-U meter reading data processing

  • Message number: 106

  • Message text: Gerät &1 AblDatum &2: Abweichung vom Vorablesestand > zulässiger Festwert

  • Show details Hide details
  • Was verursacht dieses Problem?

    Validation 96 (automatic validation) recognized that the value exceeded
    or fell below the permissible deviation. This check is only valid for
    registers that relate to a nonactive or disconnected installation, or
    for registers that are not yet allocated to an installation.

    Das System gibt eine Fehlermeldung aus und erlaubt Ihnen nicht, mit dieser Transaktion fortzufahren, bis der Fehler behoben ist.

    Devices with installation allocation:
    ----------------------------
    The deviation fixed value is stored in table TE409. It specifies the
    permissible deviation in the the last register decimal place.
    Example:
    Deviation fixed value: 5
    Previous meter reading: 100.001 kWh
    Current meter reading: 100.009 kWh
    The deviation in the last register decimal place is 8. This value is
    greater than 5 and therefore the meter reading is implausible.
    Devices without installation allocation:
    -----------------------------
    The deviation fixed value for devices without an installation
    allocation is stored in table TE437 in accordance with the unit of
    measurement for meter reading.
    Example:
    Deviation fixed value:
    5 Previous meter reading: 100.001
    kWh Current meter reading: 100.003 kWh
    The deviation in the last register decimal place is 2. This value is
    less than 5 and therefore the meter reading is plausible.

    Systemantwort

    Wie behebe ich diesen Fehler?

    The meter reading can be released or reset for later processing.

    Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE


Smart SAP Assistant

  • Was ist die Ursache und Lösung für den SAP Fehler EL106 - Gerät &1 AblDatum &2: Abweichung vom Vorablesestand > zulässiger Festwert ?




    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Sign up for our Free Essentials Plan.


Zugehörige SAP-Fehlermeldungen

Klicken Sie auf die Links unten, um die folgenden verwandten Nachrichten anzuzeigen:

Klicken Sie auf diesen Link, um alle SAP-Meldungen durchsuchen.


Rating
The AI Support Assistant is great. It provides comprehensive assistance even on the most difficult issues. I highly recommend this service.
Rate 1
John Jordan
SAP Consultant & Author