Do you have any question about this error?
Message type: E = Error
Message class: DFS_MAINT_COMMON - Message Class for DFS Maintenance
Message number: 000
Message text: Tech. StsProfil &2 für CEQ &1 weicht von and. Profilen in d. Struktur ab.
TStat profile &v2& in CEQ &v1& is not suitable for the master equipment
profile
In general, technical status aggregation from a subordinate critical
equipment to a superior critical equipment or to the master equipment is
only performed if both equipment have identical technical status
profiles.
Two scenarios are possible here:
The <ZU>technical status profile for the critical equipment selected is
not the same as </>the technical status profile for at least one
critical equipment or the master equipment used in the <ZU>superior
technical object structure</>:
A superior critical equipment or the master equipment A has a different
technical status profile from the critical equipment B selected. The
technical status aggregation for equipment A cannot consider any
notifications or orders with the technical status created for the
technical objects below the critical equipment B. The technical status
for notifications and orders below equipment B is aggregated to the
superior critical equipment as long as their technical status profiles
are identical to that for equipment B.
The <ZU>technical status profile for the chosen critical equipment
differs </>from the technical status profile for at least one critical
equipment used in the <ZU>subordinate technical object structure</>:
A subordinate critical equipment C has a different technical status
profile from the chosen critical equipment B. The bottom-up technical
status aggregation for critical equipment B cannot consider any
notifications or orders with a technical status created for technical
objects below the critical equipment C.
Ideally, only use one technical status profile for all critical
equipment and the master equipment within a single technical object
structure.
Be aware of the consequences if you choose not to follow this
recommendation.
Das System gibt eine Fehlermeldung aus und erlaubt Ihnen nicht, mit dieser Transaktion fortzufahren, bis der Fehler behoben ist.
Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE
DFS_MAINT_COMMON000
- Tech. StsProfil &2 für CEQ &1 weicht von and. Profilen in d. Struktur ab. ?Get instant SAP help. Start your 7-day free trial now.
DFS_LOG016
Ungültiges FMPO ausgewählt. Korrigieren Sie die Eingabedaten.
Selbsterklärende Nachricht Da SAP der Meinung ist, dass diese spezielle Fehlermeldung 'selbsterklärend' ist, wurden keine weiteren Informationen geg...
DFS_LOG015
Die Eingabedaten sind ungültig. Bitte prüfen Sie diese.
Selbsterklärende Nachricht Da SAP der Meinung ist, dass diese spezielle Fehlermeldung 'selbsterklärend' ist, wurden keine weiteren Informationen geg...
DFS_MAINT_COMMON001
Equipm. &1: Tech. Statusprofil &2 passt nicht zu Profil &3 für Equipm. &4
Selbsterklärende Nachricht Da SAP der Meinung ist, dass diese spezielle Fehlermeldung 'selbsterklärend' ist, wurden keine weiteren Informationen geg...
DFS_MAINT_COMMON002
Die Aggreg. des techn. Status auf höherer Strukturebene wird beeinflusst.
Was verursacht dieses Problem? Technical status aggregation at the higher structure level will be affectedSystemantwort The ?Stop Technical Statu...
Klicken Sie auf diesen Link, um alle SAP-Meldungen durchsuchen.