Do you have any question about this error?
Message type: E = Error
Message class: DB6 - DB6: Alert Monitoring and Alert Configuration
Message number: 513
Message text: Schalter DFT_MON_BUFPOOL ist nicht gesetzt
To allow meaningful monitoring of the database, you must activate this
switch.
If this switch is not set, it can lead to problems ranging from
restricting the function of the CCMS transactions to erroneous
terminations.
Activate the switch by setting the appropriate database manager
parameters using the following command:
<LB>UPDATE DBM CFG USING DFT_MON_BUFPOOL ON </>
The setting will become active at the next connection to the database.
Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE
DB6513
- Schalter DFT_MON_BUFPOOL ist nicht gesetzt ?Get instant SAP help. Start your 7-day free trial now.
DB6512
Schalter DFT_MON_BUFPOOL ist gesetzt
INCLUDE BC_DB6_OK OBJECT DOKU ID TX LANGUAGE ENFehlermeldungsextrakt aus SAP-System. Copyright SAP SE ...
DB6511
Monitoring der Pufferpools
Was verursacht dieses Problem? To allow meaningful monitoring of the database, you must activate this switch.Systemantwort If this switch is not ...
DB6514
Für den Schalter DFT_MON_BUFPOOL wurde ein ungültiger Wert gemeldet
Copy of DB6 511Was verursacht dieses Problem? To allow meaningful monitoring of the database, you must activate this switch.Systemantwort If thi...
DB6515
Monitoring des Sperrverhaltens
Copy of DB6 511 except for user entryWas verursacht dieses Problem? To allow meaningful monitoring of the database, you must activate this switch....