How To Fix CO675 - Ungültige Mengeneinheit bei Komponente & (Siehe Langtext)


SAP Error Message - Details

  • Message type: E = Error

  • Message class: CO - PPC order processing messages

  • Message number: 675

  • Message text: Ungültige Mengeneinheit bei Komponente & (Siehe Langtext)

  • Show details Hide details
  • Was verursacht dieses Problem?

    The component &V1& plant &V2& cannot be copied with the unit of
    measure &V3& entered since these cannot be converted to the base unit
    of measure &V4&. If the unit of measure entered corresponds neither to
    the base unit of measure nor to the unit of issue then the system
    calculates a conversion ratio between the unit of measure of the
    component and its base unit of measure. If this ratio is too large then
    the component is copied with the base unit of measure.

    Systemantwort

    The component is copied with the base unit of measure (or if possible
    with the unit of issue).

    Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE