How To Fix CNVMBTRFC026 - Subprojekt &1 mit Destination &2 adressiert zwei versch. Kontrollsysteme


SAP Error Message - Details

  • Message type: E = Error

  • Message class: CNVMBTRFC - Messages used in RFC Management and its objects

  • Message number: 026

  • Message text: Subprojekt &1 mit Destination &2 adressiert zwei versch. Kontrollsysteme

  • Show details Hide details
  • Was verursacht dieses Problem?

    Cause of the error
    The synchronization check finds out that there is a conflict with
    another control system. The error message give the information which
    subproject and destination is affected. In the detaild status you also
    get the information which destination is affected.

    Das System gibt eine Fehlermeldung aus und erlaubt Ihnen nicht, mit dieser Transaktion fortzufahren, bis der Fehler behoben ist.

    The check found out that in the system/client where we wanted to
    synchronize the destinations already another control system is using the
    same subproject name with an active package. You can check this by going
    into the affected system/client and calling transaction SE11 or any
    other transaction for showing the table entries. Enter the table name
    cnvmbtpack and press button 'Display'. Press button 'Contents' in the
    application toolbar. Enter the affectd subproject name into field
    subproject. Press button 'Execute' or key F8. You will see the active
    package of the subproject. If there are two active packages or a package
    with system/client data that is different from the affected control
    system then we have a conflict.
    Solving the conflict
    Option 1.
    The conflict can be solved by creating a new subproject in the control
    system where the conflict is shown. The other control system is not
    affected because the synchronization from the affected control system
    aborted and no destination data were overwritten.
    Option 2.
    In the control system where the error occurs you can change the
    destination ids. This can be done by pressing button 'SEARCH' in the
    registry 'Definition'. Before this you should create the destinations
    you need in the transaction SM59. With the search function you can
    search for your created destination. Select your destination in the
    table with the results and press button 'Use'. The destination id of the
    execution target you have selected will be replaced by your destination
    id. Do this also with the all destinations used for the affected system.
    If all destination ids are replaced do the synchronization. After this
    the synchronization status will be changed to green.

    Systemantwort

    Wie behebe ich diesen Fehler?

    Vorgehensweise für Systemadministratoren


    Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE


Smart SAP Assistant

  • Was ist die Ursache und Lösung für den SAP Fehler CNVMBTRFC026 - Subprojekt &1 mit Destination &2 adressiert zwei versch. Kontrollsysteme ?




    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.


Zugehörige SAP-Fehlermeldungen

Klicken Sie auf die Links unten, um die folgenden verwandten Nachrichten anzuzeigen:

Klicken Sie auf diesen Link, um alle SAP-Meldungen durchsuchen.


Rating
ERPlingo simplifies finding the accurate answers to SAP message errors. I now use every week. A must have tool for anyone working with SAP! Highly recommended!
Rate 1
Kent Bettisworth
Executive SAP Consultant