Do you have any question about this error?
Message type: E = Error
Message class: CLBW_META - For Generating Metadata
Message number: 018
Message text: InfoObjekt/Source & besitzt keine Transferstruktur (Langtext beachten)
When creating an InfoSource for classification or configuration data in
the BW system, the key fields of the basic InfoSource that are linked to
key fields of a OLTP basic DataSource are transferred into the
extraction structure. This only occurs if the key fields of this OLTP
basic DataSource have the same names as the key fields of the
classification DataSource. Klassifizierung-DataSource sind.
For example: a classification DataSource in the OLTP system 1CL_OMAT001
has the same key field as its corresponding basic DataSource (MATNR).
This base DataSource is linked to a basic InfoSource from the BW system
via the key field assignment, for example, MATNR <-> 0MATERIAL. In the
extraction structure of the classification InfoSource to be generated,
the key field 0MATERIAL is transferred. The prerequisite for this is
that the basis InfoSource or basis InfoObject that you entered exists in
the BW system and that it is linked with a basis DataSource from the
OLTP system. This basic DataSource has to correspond with the current
classification or configuration DataSource via key fields of the same
name. If these prerequisites are not fulfilled, the system generates a
proposal for the key fields of the extraction structure. The key fields
proposed by the system can be overwritten later, as needed.
Das System gibt eine Fehlermeldung aus und erlaubt Ihnen nicht, mit dieser Transaktion fortzufahren, bis der Fehler behoben ist.
The basic InfoSource &V1& you specified does not have a link (transfer
structure) to a basic DataSource from the OLTP system. For this reasons,
the program cannot transfer key fields from the structure of the basic
InfoSource. Check your entries and enter the correct basic InfoSource as
needed. You
can also ignore the message and continue with the transaction. In this
case, the system generates the proposals for the key fields, which you
can overwrite later as needed.
Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE
CLBW_META018
- InfoObjekt/Source & besitzt keine Transferstruktur (Langtext beachten) ?Get instant SAP help. Start your 7-day free trial now.
CLBW_META017
Maximale Anzahl von Attributen überschritten (Langtext beachten)
Was verursacht dieses Problem? You want to extend an InfoSource. This will then have more than 255 attributes.Systemantwort There is not enough s...
CLBW_META016
DataSource ist schon zugeordnet
Selbsterklärende Nachricht Da SAP der Meinung ist, dass diese spezielle Fehlermeldung 'selbsterklärend' ist, wurden keine weiteren Informationen geg...
CLBW_META019
Kein Eintrag im Feld "Basis-InfoObjekt/Source" (Langtext beachten)
Was verursacht dieses Problem? When creating an InfoSource for classification or configuration data in the BW system, the key fields of the basic I...
CLBW_META020
Basis-InfoObjekt/Source &1 ist nicht relevant (Langtext beachten)
Was verursacht dieses Problem? When creating an InfoSource for classification or configuration data in the BW system, the key fields of the basic I...
Klicken Sie auf diesen Link, um alle SAP-Meldungen durchsuchen.