Do you have any question about this error?
Message type: E = Error
Message class: C0 - PP-PI: Messages for PI Sheet and Syntax Checker
Message number: 631
Message text: Meldungsart & in Phase &, Prozeßvorgabe & ist nicht definiert
In process instruction &V3& for phase &V2& of the process order, a
process message of the category &V1& is requested. However, the
process message category &V1& is not defined in Customizing. For this
reason, the requested data cannot be reported.
Das System gibt eine Fehlermeldung aus und erlaubt Ihnen nicht, mit dieser Transaktion fortzufahren, bis der Fehler behoben ist.
RESET N1
Check
the definition of the process instruction &V3& for phase &V2& of the
process order
<DS:TRAN.COR2>Change process order</>
the definition of the message categories in Customizing
If the desired message category does not yet exist in the system,
define it in Customizing.
If the wrong message category has been specified in the process order,
you have the following options:
<ZH>In the case of PI sheets with test function:</>
Correct the process instruction &V3& for phase &V2& of the process
order.
Create a new control recipe and maintain the corresponding PI sheet.
<ZH>In the case of productive PI sheets:</>
Errors in the process instruction cannot be corrected for the current
PI sheet.
If necessary, deactivate the process instruction in the PI sheet.
Manually create the process message to be used for reporting the
desired value.
INCLUDE 'NA_PLNREZ_HINW' OBJECT DOKU ID TX LANGUAGE E
<DS:TRAN.C202>Change master recipe</>
Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE
C0631
- Meldungsart & in Phase &, Prozeßvorgabe & ist nicht definiert ?Get instant SAP help. Start your 7-day free trial now.
C0630
Keine Berechtigung zum Archivieren in Werk & und Adresse &
Was verursacht dieses Problem? You do not have the authorization to archive PI sheets for control address &V2& in plant &V1&. INCLU...
C0629
Keine Berechtigung zum Modifizieren in Werk & und Adresse &
Was verursacht dieses Problem? You do not have the authorization to change PI sheets for control address &V2& in plant &V1&. INCLUD...
C0632
Fehler bei der Aufbereitung der Archiv-/Druckparameter
Was verursacht dieses Problem? An internal error occurred when the archive or print parameters were edited.Systemantwort Das System gibt eine Feh...
C0633
***Fehler beim Zugriff auf das Archiv
Selbsterklärende Nachricht Da SAP der Meinung ist, dass diese spezielle Fehlermeldung 'selbsterklärend' ist, wurden keine weiteren Informationen geg...