Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: C0 - PP-PI: Messages for PI Sheet and Syntax Checker
Message number: 209
Message text: #NAME?
The process instruction is of type "dynamic function call".
The following characteristics are used to assign the interface
parameters of the calling function module to the process instruction:
PPPI_EXPORT_PARAMETER
PPPI_CHANGING_PARAMETER
PPPI_IMPORT_PARAMETER
For the system to be able to process this parameter correctly, you must
define the value to be transferred for this parameter or the variable
used in the PI sheet for the value to be transferred immediately after
this parameter.
However, the value to be transferred or the variable is missing for at
least one parameter in the process instruction.
Das System gibt eine Fehlermeldung aus und erlaubt Ihnen nicht, mit dieser Transaktion fortzufahren, bis der Fehler behoben ist.
For export parameters:
Define a constant value or a variable whose value is to be transferred
to the function module.
For import and changing parameters:
Assign the variable defined in the PI sheet for the value to be
transferred.
For changing parameters, the variable must have been defined in a
preceding process instruction for the same control recipe destination
or PI sheet.
<DS:TX.NA_INST_FUPAR_VALC>Assigning a Constant Value to a Parameter</>
<DS:TX.NA_INST_FUPAR_VALV>Assigning a Variable to a Characteristic</>
<DS:TX.NA_INST_VAR>Defining a Variable</>
Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE
C0209
- #NAME? ?Get instant SAP help. Sign up for our Free Essentials Plan.
C0208
- Bitte definieren Sie nach & & die Variable für den Parameterwert
Was verursacht dieses Problem? The process instruction is of type "dynamic function call". Characteristic &V1& &V2& assig...
C0207
- Bitte definieren Sie nach & & den zu übergebenden Wert
Was verursacht dieses Problem? The process instruction is of type "dynamic function call". With characteristic &V1& &V2&,...
C0210
#NAME?
Was verursacht dieses Problem? The process instruction is of type "process data request". Characteristic PPPI_DEFAULT_VARIABLE defines a ...
C0211
- Das Merkmal & & ist an dieser Stelle nicht vorgesehen
Was verursacht dieses Problem? Characteristic &V2& cannot be used in position &V1& for one of the following reasons: The characteri...
Klicken Sie auf diesen Link, um alle SAP-Meldungen durchsuchen.