Do you have any question about this error?
Message type: E = Error
Message class: BIL - General billing
Message number: 108
Message text: Gasfaktor &1 kann nicht eindeutig bestimmt werden
During <ZH>determination of the gas factor</>, the following error
occurred: It was not possible to determine the gas factor <ZH>uniquely
</>.
To avoid inconsistencies, the system terminates processing.
Check whether you have entered <ZH>all required</> meter readings using
the <ZH>correct meter reading category</> for a device. See the
following notes. If you are unable to solve the problem after reading
these, please contact SAP.
<ZH><ZU><ZK>Comments</></></>
<ZK>For <DS:DE.E_QD_PROC>quantity determination procedure</> 03 -
Quantity Determination During Meter Reading, it is very important that a
<ZH>unique</> </><ZH><ZK>gas factor can be determined</></> for the
<ZK>period between a meter reading and the previous meter reading.</>
<ZK>This includes not changing the </><ZH><ZK>gas procedure</></><ZK>
during this period unless an additional </><ZH><ZK>actual</></><ZK>meter
reading is available for the proration time ( activity day- 1 ).</>
<ZK>The gas procedure implemented must also be set up so that it does
not produce historical factors during this period. This means that you
usually require gas procedures whose components are calculated by </>
<ZH><ZK>averaging</></><ZK> or by using</><ZH><ZK>constant factors</></>
<ZK>.</>
<ZK>If you change the fields </><ZH><ZK>Gas Procedure,</></><ZK> </><ZH>
<ZK>Fixed Temperature</></><ZK>and </><ZH><ZK>Volume Correction Factor
</></><ZK> ( from register), which you change using the transactions
<ZH>EG70</> or <ZH>EC30</>, you also require </><ZH><ZK>actual</></><ZK>
meter readings.</>
<ZK>For additional notes about using the correct meter reading type, see
the long text for the following message <DS:NA.EE_QD106>EE_QD 106</></>
Das System gibt eine Fehlermeldung aus und erlaubt Ihnen nicht, mit dieser Transaktion fortzufahren, bis der Fehler behoben ist.
Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE
BIL108
- Gasfaktor &1 kann nicht eindeutig bestimmt werden ?Get instant SAP help. Start your 7-day free trial now.
BIL107
Umwandlung in Zwischendimension mit MengenermVerf. &1 nicht möglich
Was verursacht dieses Problem? You are using a variant program to determine a quantity with an interim dimension. However, this is not possilbe wit...
BIL106
Dynam.Periodenstrg ist bei Mengenermittlungsverfahren &1 nicht erlaubt
Was verursacht dieses Problem? The rate category &v2& uses dynamic period control (DPC). The installation contains devices with quantity de...
BIL109
Geben Sie eine Tarifart an, die die selbe Rundungsart aufweist
Was verursacht dieses Problem? Different rounding types were found for the register in installations &v1& and &v2& for the period f...
BIL110
Geben Sie ein Schema mit konditionalem Abrechnungsprogramm an
Was verursacht dieses Problem? You have specified in rate category &v2& that a conditional billing program can be executed. However, the sc...
Klicken Sie auf diesen Link, um alle SAP-Meldungen durchsuchen.