How To Fix AJ346 - Nicht plausibler Überlauf bei Gerät &1 Zw &2 Von-Datum &3 Bis-Datum &4


SAP Error Message - Details

  • Message type: E = Error

  • Message class: AJ - Billing program

  • Message number: 346

  • Message text: Nicht plausibler Überlauf bei Gerät &1 Zw &2 Von-Datum &3 Bis-Datum &4

  • Show details Hide details
  • Was verursacht dieses Problem?

    For device &v1&, <ZK>register</> &v2&, the rounded meter reading for
    date &v3& is greater than the rounded meter reading for date &v4&.
    However, the amount of the difference is less than 1.
    The error may have caused by an artificial meter overflow resulting from
    the rounding. This problem may occur, for example, if the meter reading
    rounding changed due to a rate change.

    Systemantwort

    This error can occur in billing in two processes:
    During rounding of the actual meter reading results to the meter reading
    rounding
    During rounding of the meter reading results generated artificially as a
    result of proration
    In this case, the specified to-date &v4& is the proration date up to
    which a result was calculated. This result is rounded and compared to
    the result taken or calculated earlier. An artificial overflow was
    determined in this process.

    Wie kann das passieren?

    You have recorded three meter readings. Two of them were read with three
    decimal places. After the second result (10.957) was entered, the rate
    changed, which resulted in a change in the meter reading rounding from
    three to no decimal places (DP).
    |-------------------|
    0 3 DP 10.123
    |------------------|
    10.123 3 DP 10.957
    |------------------|
    10.957 0 DP 20
    Rounding results in the following readings:
    0 10.123 10 20
    10.957 was rounded down to 10 (minimum of meter reading roundings 3 DP
    and 0 DP). However, the reading is then lower than the previous reading
    (10.123). As a result of the rounding, an artificial meter reading
    overflow was generated.
    The system cannot continue processing of the billing order.

    Systemantwort

    Das System gibt eine Fehlermeldung aus und erlaubt Ihnen nicht, mit dieser Transaktion fortzufahren, bis der Fehler behoben ist.

    Wie behebe ich diesen Fehler?

    Change the meter reading results in a way that rounding cannot result in
    a meter overflow.
    If the error resulted from artificially generated proration readings,
    you can enter an estimated result for proration date &v4& or you can
    change the results before and after the proration date in such a way
    that the error does not occur (for example, you can manually round the
    results down to zero decimal places).
    Note
    In some cases, the error can also occur in other situations, for
    example, if an estimated meter reading exists in the database and there
    is a meter overflow as a result of the next actual meter reading.
    If this occurs, you can also use the procedure described above by adding
    a new estimated meter reading or by changing the existing one.
    We recommend that you also do this to replace obsolete estimatons with
    more exact new estimations (for example, interpolation instead of
    extrapolation).

    Vorgehensweise für Systemadministratoren


    Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE


Smart SAP Assistant

  • Was ist die Ursache und Lösung für den SAP Fehler AJ346 - Nicht plausibler Überlauf bei Gerät &1 Zw &2 Von-Datum &3 Bis-Datum &4 ?




    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.


Zugehörige SAP-Fehlermeldungen

Klicken Sie auf die Links unten, um die folgenden verwandten Nachrichten anzuzeigen:

Klicken Sie auf diesen Link, um alle SAP-Meldungen durchsuchen.


Rating
ERPlingo simplifies finding the accurate answers to SAP message errors. I now use every week. A must have tool for anyone working with SAP! Highly recommended!
Rate 1
Kent Bettisworth
Executive SAP Consultant