Do you have any question about this error?
Message type: E = Error
Message class: AJ - Billing program
Message number: 197
Message text: Gerät &1 ZW &2 Zeit &3-&4: Falsches Ab-Dat. KompressTabelle aus User-Exit
A volume correction factor procedure that requires calculation of
compressibility and/or supercompressibility through user exit <LS>
EXIT_SAPLEA54_001</> is active for the specified register. In this
case, however, the value could not be calculated because return table
y_table_compr_factors has an incorrect structure. The from-date of the
earliest entry does not correspond to the from-date passed on in import
parameter X_DATE_FROM.
Das System gibt eine Fehlermeldung aus und erlaubt Ihnen nicht, mit dieser Transaktion fortzufahren, bis der Fehler behoben ist.
First analyze the cause of the termination in your user-defined user
exit. Inform the person who is responsible for programming the user
exit.
The person responsible for the program should note the following:
In the IS-U menu, choose <LS>Billing execution</> -> <LS>Billing
analysis</>.
Choose <LS>Settings</> -> <LS>General</>, then set the <LS>Debugging on
</> indicator.
Start a billing simulation with the affected contract. Enter TGHUEXIT
in the <LS>Breakpoint at</> field.
You branch immediately to the point where your user exit is called, and
you may be able to localize the error in debugging.
Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE
AJ197
- Gerät &1 ZW &2 Zeit &3-&4: Falsches Ab-Dat. KompressTabelle aus User-Exit ?Get instant SAP help. Start your 7-day free trial now.
AJ196
Gerät &1 ZW &2 Zeit &3-&4: Kompressibilität aus User-Exit fehlt
Was verursacht dieses Problem? A volume correction factor procedure that requires calculation of compressibility and/or supercompressibility throug...
AJ195
Gerät &1 ZW &2 Zeit &3-&4: Kompressibilität via User-Exit: Fehler
Was verursacht dieses Problem? A volume correction factor procedure that requires calculation of compressibility and/or supercompressibility throug...
AJ198
Gerät &1 ZW &2 Zeit &3-&4: Falsches Bis-Dat KompressTabelle aus User-Exit
Was verursacht dieses Problem? A volume correction factor procedure that requires calculation of compressibility and/or supercompressibility throug...
AJ199
Gerät &1 ZW &2 Zeit &3-&4: KompressTab aus User-Exit inkonsistent
Was verursacht dieses Problem? A volume correction factor procedure that requires calculation of compressibility and/or supercompressibility throug...