Black Friday is ending this Friday! 40% off with coupon CYBER40 - Sign up here →
Message type: E = Error
Message class: HH - (Long) text for check tool 'infcfgcheck'
Message number: 039
Message text: Editez le fichier Informix ONCONFIG
You configured ONCONFIG parameter 'TAPEBLK' or 'LTAPEBLK'
to be greater than '128'.
Parameter 'TAPEBLK' specifies the block size with which the backup
tool 'ontape' saves the dbspaces on tape.
'LTAPEBLK' specifies the block size with which
'ontape' saves the logical logs on tape.
If you define 'ontape', your backup will fail since SNI tape stations
can only handle a maximum of '128' at the moment
(see Note 53970).
To reconfigure 'TAPEBLK' or 'LTAPEBLK', edit file
'$INFORMIXDIR/etc/$ONCONFIG' (as user 'informix')('ontape' should not
be running at the time of editing).
Extrait du message d'erreur du système SAP. Copyright SAP SE.
Get instant SAP help. Sign up for our Free Essentials Plan.
HH038 Editez le fichier Informix ONCONFIG
Quelle est la cause de ce problème? You set ONCONFIG parameter 'LTAPEDEV' to '/dev/null'. 'LTAPEDEV' specifies the de...
HH037 Editez le fichier Informix ONCONFIG
Quelle est la cause de ce problème? You set ONCONFIG parameter 'TAPEDEV' to '/dev/null'. 'TAPEDEV' specifies the devi...
HH040 Editez le fichier Informix ONCONFIG
Quelle est la cause de ce problème? Your configuration of the ONCONFIG parameter 'LTXHWM' (long-transaction high-water mark) differs from...
HH041 Editez le fichier Informix ONCONFIG
Quelle est la cause de ce problème? You have configured the ONCONFIG parameter 'LTXEHWM' (long-transaction [exclusive- access] high-water...