Do you have any question about this error?
Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 379
Message text: App.&1 cdrn &2 : aucun enr. de planning réel trouvé ds période de &3 à &4
When you upload periodic meter reading results without meter reading
reasons, meter reading order creation is started internally. The
foundation for creating orders is a schedule record that contains the
planning data.
An order is only created when a schedule record is found. The system
searches for the planned meter reading date from the schedule record.
If the planned meter reading date does not agree with the actual meter
reading date, the input is rejected. Any tolerance configured in table
TE410 (parameters for recording meter reading data) is taken into
account in the process.
The system attempted to find a schedule record between &v3& and &v4&.
Le système émet un message d'erreur et ne vous permettra pas de poursuivre cette transaction tant que l'erreur n'est pas résolue.
Check the data.
If the grace period has been exceeded, enter the order manually.
If no schedule record exists for this period, generate a schedule
record.
Extrait du message d'erreur du système SAP. Copyright SAP SE.
EL379
- App.&1 cdrn &2 : aucun enr. de planning réel trouvé ds période de &3 à &4 ?Get instant SAP help. Start your 7-day free trial now.
EL378
App. &1 cdrn &2 : pas de remplacement d'app. à la date de relevé &3
Quelle est la cause de ce problème? During entry, you specified a meter reading note for which control note 05 (device replacement) is defined. The...
EL377
L'occultation du calcul de facturation ne se justifie pas.
Quelle est la cause de ce problème? You tried to prevent billing. This does not make sense because the meter reading does not trigger billing, and ...
EL380
App. &1 cdrn &2 date rel. &3 : estim. imposs. car cat. de tarif non gérée
Quelle est la cause de ce problème? No <DS:DE.TARIFART>rate type</> can be determined in the installation structure of the register. Th...
EL381
Le motif de relevé 08 (pose technique) n'est permis qu'au niveau appareil
Quelle est la cause de ce problème? You tried to make a single entry with meter reading reason 08 (technical installation) at customer, contract, o...
Cliquez sur ce lien pour rechercher tous les messages SAP.