Do you have any question about this error?
Message type: E = Error
Message class: AJ - Billing program
Message number: 198
Message text: Appareil &1 Cad &2 hre &3-&4 : "dte au" tble compr. à partir du user-exit
A volume correction factor procedure that requires calculation of
compressibility and/or supercompressibility through user exit <LS>
EXIT_SAPLEA54_001</> is active for the specified register. In this
case, however, the value could not be calculated because return table
y_table_compr_factors has an incorrect structure. The to-date of the
most recent entry does not correspond to the to-date passed on in
import parameter X_DATE_TO.
Le système émet un message d'erreur et ne vous permettra pas de poursuivre cette transaction tant que l'erreur n'est pas résolue.
First analyze the cause of the termination in your user-defined user
exit. Inform the person who is responsible for programming the user
exit.
The person responsible for the program should note the following:
In the IS-U menu, choose <LS>Billing execution</> -> <LS>Billing
analysis</>.
Choose <LS>Settings</> -> <LS>General</>, then set the <LS>Debugging on
</> indicator.
Start a billing simulation with the affected contract. Enter TGHUEXIT
in the <LS>Breakpoint at</> field.
You branch immediately to the point where your user exit is called, and
you may be able to localize the error in debugging.
Extrait du message d'erreur du système SAP. Copyright SAP SE.
AJ198
- Appareil &1 Cad &2 hre &3-&4 : "dte au" tble compr. à partir du user-exit ?Get instant SAP help. Start your 7-day free trial now.
AJ197
Appareil &1 Cad &2 pér. &3-&4: dte "du" tble compr. à partir du user-exit
Quelle est la cause de ce problème? A volume correction factor procedure that requires calculation of compressibility and/or supercompressibility t...
AJ196
Appar. &1 Cadran &2 pér. &3-&4 : compressibilité à part. user-exit mqe
Quelle est la cause de ce problème? A volume correction factor procedure that requires calculation of compressibility and/or supercompressibility t...
AJ199
App. &1 cadran &2 hre &3-&4 : tble compr. à part. user-exit incohérente.
Quelle est la cause de ce problème? A volume correction factor procedure that requires calculation of compressibility and/or supercompressibility t...
AJ200
La vérification des unités de mesure requiert au moins deux opérandes.
Message auto-explicatif Étant donné que SAP estime que ce message d'erreur spécifique est 'auto-explicatif', aucune autre information n'a été fou...
Cliquez sur ce lien pour rechercher tous les messages SAP.