Do you have any question about this error?
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 310
Message text: No están activ.las rutinas de SAP p.gas nat.: se reinicializ.los result.
The SAP routines for natural gas are not activated. Thus, the system
will not calculate a base density or base heating value using the
formulas delivered with the standard SAP system. You can activate the
formulas in Customizing. You then agree to the conditions specified in
the customizing IMG description for this activity (Transaction O594).
1) The system will reset the base density and base heating result to
zero. Energy values will be converted into each other regardless of the
fact that their units of measure are specified at different combustion
temperatures. You can utilize Business Add-In OIB_QCI_NATURAL_GAS to
implement you own formula for the calculation.
Use methods CALC_BASE_DENSITY and CALC_BASE_HEATINGVALUE of BAdI
OIB_QCI_NATURAL_GAS to determine the base heating value and density.
Use method CORR_COMBUSTION_ENERGY of BAdI OIB_QCI_NATURAL_GAS to take
into account different combustion temperatures for energy units of
measure.
If you have implemented the AGA c-code routines, the base density can be
calculated by these external program routines.
2) The base heating value and base density in SI units are cleared as
well. You have to activate and implement the method
DENSITY_HVALUE_CONVERT of BAdI OIB_QCI_NATURAL_GAS with your own
conversion formulas in order to calculate these values for natural gas
in SI units. These values are required for the Quantity Conversion
Interface (QCI) if a conversion from one dimension to another is
necessary.
3) The system will reset the ideal gas volume correction factor to zero.
You have to use method CALC_IDEAL_GAS_VCF of BAdI OIB_QCI_NATURAL_GAS in
order to calculate the ideal gas volume correction factor.
El sistema emite un mensaje de error y no le permitirá continuar con esta transacción hasta que se resuelva el error.
This message can be customized to appear as an error, warning,
information or success message type (Transaction O591)
Extracto de mensaje de error del sistema SAP. Copyright SAP SE.
O3310
- No están activ.las rutinas de SAP p.gas nat.: se reinicializ.los result. ?Get instant SAP help. Start your 7-day free trial now.
O3309
Se ha transferido un ind.no válido a ICC (Interfaz de conv.cantidades)
¿Qué causa este problema? In the conversion group, you define which SAP set of formulas for the calculation of the base density and base heating v...
O3308
Se ha transferido un tp.de densidad no válido a ICC (Interfaz Conv.Ctd.)
¿Qué causa este problema? In the conversion group customizing, you define a density type for each conversion group. The following density types are...
O3311
No se ha definido la clase de poder calorífico base en el grupo de conv.
Mensaje autoexplicativo Dado que SAP cree que este mensaje de error específico 'se explica por sí mismo', no se ha proporcionado más información. ...
O3312
No se ha asignado grupo de conversión al set de datos de prop.físicas
Mensaje autoexplicativo Dado que SAP cree que este mensaje de error específico 'se explica por sí mismo', no se ha proporcionado más información. ...
Haga clic en este enlace para buscar todos los mensajes de SAP.