How To Fix O3310 - No están activ.las rutinas de SAP p.gas nat.: se reinicializ.los result.


SAP Error Message - Details

  • Message type: E = Error

  • Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)

  • Message number: 310

  • Message text: No están activ.las rutinas de SAP p.gas nat.: se reinicializ.los result.

  • Show details Hide details
  • ¿Qué causa este problema?

    The SAP routines for natural gas are not activated. Thus, the system
    will not calculate a base density or base heating value using the
    formulas delivered with the standard SAP system. You can activate the
    formulas in Customizing. You then agree to the conditions specified in
    the customizing IMG description for this activity (Transaction O594).

    Respuesta del sistema

    1) The system will reset the base density and base heating result to
    zero. Energy values will be converted into each other regardless of the
    fact that their units of measure are specified at different combustion
    temperatures. You can utilize Business Add-In OIB_QCI_NATURAL_GAS to
    implement you own formula for the calculation.
    Use methods CALC_BASE_DENSITY and CALC_BASE_HEATINGVALUE of BAdI
    OIB_QCI_NATURAL_GAS to determine the base heating value and density.
    Use method CORR_COMBUSTION_ENERGY of BAdI OIB_QCI_NATURAL_GAS to take
    into account different combustion temperatures for energy units of
    measure.
    If you have implemented the AGA c-code routines, the base density can be
    calculated by these external program routines.
    2) The base heating value and base density in SI units are cleared as
    well. You have to activate and implement the method
    DENSITY_HVALUE_CONVERT of BAdI OIB_QCI_NATURAL_GAS with your own
    conversion formulas in order to calculate these values for natural gas
    in SI units. These values are required for the Quantity Conversion
    Interface (QCI) if a conversion from one dimension to another is
    necessary.
    3) The system will reset the ideal gas volume correction factor to zero.
    You have to use method CALC_IDEAL_GAS_VCF of BAdI OIB_QCI_NATURAL_GAS in
    order to calculate the ideal gas volume correction factor.

    ¿Cómo arreglar este error?

    El sistema emite un mensaje de error y no le permitirá continuar con esta transacción hasta que se resuelva el error.

    Procedimiento para Administradoras de Sistemas

    This message can be customized to appear as an error, warning,
    information or success message type (Transaction O591)

    Extracto de mensaje de error del sistema SAP. Copyright SAP SE.


Smart SAP Assistant

  • ¿Cuál es la causa y la solución del error de SAP O3310 - No están activ.las rutinas de SAP p.gas nat.: se reinicializ.los result. ?




    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.


Mensajes de error de SAP relacionados

Haga clic en los enlaces a continuación para ver los siguientes mensajes relacionados:

Haga clic en este enlace para buscar todos los mensajes de SAP.


Rating
The AI Support Assistant is great. It provides comprehensive assistance even on the most difficult issues. I highly recommend this service.
Rate 1
John Jordan
SAP Consultant & Author