Do you have any question about this error?
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 231
Message text: ICC: se sustituyen los valores y unidades de la temp.y presión base
In the conversion group, an indicator is set to activate additional
conversion routines. The routines convert the base density or the base
heating value that was calculated by the system to create a new base
density or heating value.
The new base density and the new base heating value are converted to a
set of new base conditions. The new base conditions are determined by
the temperature and pressure values defined in the base heating value
and base density unit of measure. Those units of measure are defined in
the conversion group.
The additional conversion will only be carried out if the unit of
measure maintained in the conversion group for the base density or base
heating value is itself maintained in customizing with additional
parameters (Maintain units of measure ). This indicator can be set in
order to separate the base conditions at which external conversion
routines operate from the base conditions at which the calculated
parameters are stored in the system. The system will then produce a
warning message to inform you that the base density or base heating
value is being converted. For densities, a test density unit has to be
entered for this function in order to carry out the additional
conversion.
El sistema emite un mensaje de error y no le permitirá continuar con esta transacción hasta que se resuelva el error.
Extracto de mensaje de error del sistema SAP. Copyright SAP SE.
O3231
- ICC: se sustituyen los valores y unidades de la temp.y presión base ?Get instant SAP help. Start your 7-day free trial now.
O3230
Se graban & sets propuesta inactivos y se deben activar antes de usarse
¿Qué causa este problema? You have maintained several default sets and saved the data. However, not all default sets have been activated . This is ...
O3229
ICC: Se sustituyen valores y unidades de temperatura test y presión test
¿Qué causa este problema? The system will neglect the parameters entered as test conditions for the test density and test heating value, and use ...
O3232
ICC: los parám.de la dens.base y del poder caloríf.base son contradict.
¿Qué causa este problema? You have maintained a unit of measure for the base density of a natural gas in the conversion group that is maintained in...
O3233
ICC: No existe ningún ID de dimensión Sin dimensión
¿Qué causa este problema? The system tried to retrieve one unit of measure with the "dimensionless" dimension, but not one unit has been ...
Haga clic en este enlace para buscar todos los mensajes de SAP.