How To Fix IU597 - Tabla &: No es posible la conversión incremental


IU597 - Overview

  • Message type: E = Error

  • Message class: IU - Incremental Conversion (ICNV)

  • Message number: 597

  • Message text: Tabla &: No es posible la conversión incremental

  • Show details Hide details
  • ¿Qué causa este problema?

    You tried to enter an incorrect table type for incremental conversion.
    Only transparent tables and table clusters may be entered.
    Explanation
    Transparent tables, table clusters and logical cluster tables can be
    converted wth Transaction ICNV. Pooled tables and table pools, on the
    other hand, cannot be incrementally converted.
    If a logical cluster table should be converted, make sure that the
    underlying table cluster is always entered for converson. All other
    tables contained in the table cluster are also converted, even if their
    field list or field definition was not changed. It therefore makes
    sense to bundle all changes to logical tables of a table cluster and to
    execute them together.

    Respuesta del sistema

    The table is not marked for incremental conversion.

    ¿Cómo arreglar este error?

    Use the Database Utility (Transaction SE14) for the conversion.

    Extracto de mensaje de error del sistema SAP. Copyright SAP SE.


IU597 - Details








Instant HelpGet instant SAP help. Sign up for our Free Essentials Plan.


Mensajes de error de SAP relacionados

Haga clic en los enlaces a continuación para ver los siguientes mensajes relacionados:

Haga clic en este enlace para buscar todos los mensajes de SAP.


Rating
ERPlingo simplifies finding the accurate answers to SAP message errors. I now use every week. A must have tool for anyone working with SAP! Highly recommended!
Rate 1
Kent Bettisworth
Executive SAP Consultant