Black Friday is ending this Friday! 40% off with coupon CYBER40 - Sign up here

Close

How To Fix AJ788 - P.fecha lectura &1 fecha gas es inconsistente p.aparato &3, numerador &3


AJ788 - Overview

  • Message type: E = Error

  • Message class: AJ - Billing program

  • Message number: 788

  • Message text: P.fecha lectura &1 fecha gas es inconsistente p.aparato &3, numerador &3

  • Show details Hide details
  • ¿Qué causa este problema?

    Gas date &v4& is later than the meter reading date &v1& from device &v2&
    , register &v3&. This can happen if a default value 0 is entered for the
    <zK><LS>Gas Date Control in Months</></> in the <ZK><LS>Define
    Allocation Dates for Gas</></> and the scheduled and actual meter
    reading dates are in different months. Processing is cancelled.

    El sistema emite un mensaje de error y no le permitirá continuar con esta transacción hasta que se resuelva el error.

    IF&[SWITCH]ISU_QD_EHP6&='X'
    One possible cause of the error is that enhancements were not
    implemented correctly when the gas date was changed during meter reading
    data processing. The enhancements affected by this are:
    User exit EDMMR002
    BAdI ISU_QD_GAS_DATE_CHANGE for enhancement spot ISU_QD_MR
    ENDIF

    Respuesta del sistema

    The system terminates processing.

    ¿Cómo arreglar este error?

    You have the following options:
    Select a default higher than 0 in the <LS>Define Allocation Dates for
    Gas</> table
    Check and use the enhancement <ZK><LS>Change Gas Date in Meter Reading
    Data Processing</></> (EDMMR002) to change the gas date to the meter
    reading date when a meter reading result is entered.

    This only applies however if quantity determination procedure 02 - <ZK>
    <LS>Quantity Determination During Billing</></> is used.
    To change the gas date to the meter reading date during entry of the
    meter reading results, check and use the implementation of the BAdI
    ISU_QD_GAS_DATE_CHANGE in the enhancement spot ISU_QD_MR <ZK><LS>Change
    Gas Date in Meter Reading Data Processing</></>
    This only applies if quantity determination procedure 03 - <ZK><LS>
    Quantity Determination During Meter Reading</></> has been defined.
    ENDIF

    Procedimiento para Administradoras de Sistemas


    Extracto de mensaje de error del sistema SAP. Copyright SAP SE.


AJ788 - Details








Instant HelpGet instant SAP help. Sign up for our Free Essentials Plan.


Mensajes de error de SAP relacionados

Haga clic en los enlaces a continuación para ver los siguientes mensajes relacionados:

Haga clic en este enlace para buscar todos los mensajes de SAP.


Rating
ERPlingo simplifies finding the accurate answers to SAP message errors. I now use every week. A must have tool for anyone working with SAP! Highly recommended!
Rate 1
Kent Bettisworth
Executive SAP Consultant