How To Fix AJ788 - P.fecha lectura &1 fecha gas es inconsistente p.aparato &3, numerador &3


SAP Error Message - Details

  • Message type: E = Error

  • Message class: AJ - Billing program

  • Message number: 788

  • Message text: P.fecha lectura &1 fecha gas es inconsistente p.aparato &3, numerador &3

  • Show details Hide details
  • ¿Qué causa este problema?

    Gas date &v4& is later than the meter reading date &v1& from device &v2&
    , register &v3&. This can happen if a default value 0 is entered for the
    <zK><LS>Gas Date Control in Months</></> in the <ZK><LS>Define
    Allocation Dates for Gas</></> and the scheduled and actual meter
    reading dates are in different months. Processing is cancelled.

    El sistema emite un mensaje de error y no le permitirá continuar con esta transacción hasta que se resuelva el error.

    IF&[SWITCH]ISU_QD_EHP6&='X'
    One possible cause of the error is that enhancements were not
    implemented correctly when the gas date was changed during meter reading
    data processing. The enhancements affected by this are:
    User exit EDMMR002
    BAdI ISU_QD_GAS_DATE_CHANGE for enhancement spot ISU_QD_MR
    ENDIF

    Respuesta del sistema

    The system terminates processing.

    ¿Cómo arreglar este error?

    You have the following options:
    Select a default higher than 0 in the <LS>Define Allocation Dates for
    Gas</> table
    Check and use the enhancement <ZK><LS>Change Gas Date in Meter Reading
    Data Processing</></> (EDMMR002) to change the gas date to the meter
    reading date when a meter reading result is entered.

    This only applies however if quantity determination procedure 02 - <ZK>
    <LS>Quantity Determination During Billing</></> is used.
    To change the gas date to the meter reading date during entry of the
    meter reading results, check and use the implementation of the BAdI
    ISU_QD_GAS_DATE_CHANGE in the enhancement spot ISU_QD_MR <ZK><LS>Change
    Gas Date in Meter Reading Data Processing</></>
    This only applies if quantity determination procedure 03 - <ZK><LS>
    Quantity Determination During Meter Reading</></> has been defined.
    ENDIF

    Procedimiento para Administradoras de Sistemas


    Extracto de mensaje de error del sistema SAP. Copyright SAP SE.


Smart SAP Assistant

  • ¿Cuál es la causa y la solución del error de SAP AJ788 - P.fecha lectura &1 fecha gas es inconsistente p.aparato &3, numerador &3 ?




    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.


Mensajes de error de SAP relacionados

Haga clic en los enlaces a continuación para ver los siguientes mensajes relacionados:

Haga clic en este enlace para buscar todos los mensajes de SAP.


Rating
ERPlingo's SAP support assistant is amazing. Saves me countless hours trying to solve complex SAP issues myself. It's a real game changer!
Rate 1
Thomas Michael
SAP Consultant, Author & Speaker