How To Fix ACC_AA124 - Se ha reinicializado la activación del flag de Customizing PARALLEL_VAL


SAP Error Message - Details

  • Message type: E = Error

  • Message class: ACC_AA - Message Class for Function Group ACC_AA

  • Message number: 124

  • Message text: Se ha reinicializado la activación del flag de Customizing PARALLEL_VAL

  • Show details Hide details
  • ¿Qué causa este problema?

    Using the view <AB>V_T093BSN_PARVAL</>, you have transported the
    activation of the Customizing switch for the business function <LS>
    FI-AA, Parallel Valuation</> (<AB>FIN_AA_PARALLEL_VAL</>) to this
    system.
    However, the current state of this system does <ZH>not</> allow this
    activation.
    For more detailed information about the errors that occurred, see the
    transport log for view <AB>V_T093BSN_PARVAL</> or execute the
    transaction <LS>Check If Can Be Activated</> (<AB>FAA_CHECK_ACTIVATION
    </>).

    Respuesta del sistema

    To prevent postings while the state of the system is inconsistent, the
    system reset the status of the Customizing switch to <LS>In Preparation
    </>.
    When the system has this status, <ZH>no</> postings are possible in
    Asset Accounting.

    ¿Cómo arreglar este error?

    To correct the error that is mentioned in the transport log, you have to
    ensure that the state of Customizing for Asset Accounting is consistent.
    Execute transaction <AB>FAA_CHECK_ACTIVATION</> before you transport the
    activation of the Customizing switch for business function <AB>
    FIN_AA_PARALLEL_VAL</> to this system again.
    Make sure that the asset balance sheet values were updated completely in
    Asset Accounting before you import the activation.
    Note:
    As an alternative to importing again, you can use transaction <AB>
    FAA_DO_ACTIVATION </> to perform the activation in the target system. In
    a test system, you can activate the Customizing switch in this way
    despite the errors found during the check.

    Procedimiento para Administradoras de Sistemas

    El sistema emite un mensaje de error y no le permitirá continuar con esta transacción hasta que se resuelva el error.


    Extracto de mensaje de error del sistema SAP. Copyright SAP SE.


Smart SAP Assistant

  • ¿Cuál es la causa y la solución del error de SAP ACC_AA124 - Se ha reinicializado la activación del flag de Customizing PARALLEL_VAL ?




    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.


Mensajes de error de SAP relacionados

Haga clic en los enlaces a continuación para ver los siguientes mensajes relacionados:

Haga clic en este enlace para buscar todos los mensajes de SAP.


Rating
ERPlingo's SAP support assistant is amazing. Saves me countless hours trying to solve complex SAP issues myself. It's a real game changer!
Rate 1
Thomas Michael
SAP Consultant, Author & Speaker