How To Fix WXP679 - Break-down &1 does not exist in system


SAP Error Message - Details

  • Message type: E = Error

  • Message class: WXP - Retail Planning

  • Message number: 679

  • Message text: Break-down &1 does not exist in system

  • Show details Hide details
  • What causes this issue?

    You have assigned <DS:DE.WISP_BREAKD>break-down</> &V1& to
    <DS:DE.WISP_PLINT>interface</> &V2&. This break-down was not entered in
    the system and has since been deleted.

    System Response

    How to fix this error?

    Create break-down &V1& in the system or assign an existing break-down
    to interface &V2& (for the planning scenario/step &V3&/&V4&).

    Procedure for System Administrators

    The system issues an error message and will not allow you to continue with this transaction until the error is resolved.


    Error message extract from SAP system. Copyright SAP SE.


Smart SAP Assistant

  • What is the cause and solution for SAP error message WXP679 - Break-down &1 does not exist in system ?

    SAP Error Message:
    WXP679 Break-down &1 does not exist in system


    Meaning / Cause:

    This error occurs when the system tries to access or reference a "Break-down" (often a breakdown structure, breakdown element, or a related object) identified by the placeholder &1 (which will be replaced by the actual breakdown ID in the runtime message), but it cannot find this object in the system database.

    In SAP, "Break-down" typically refers to a hierarchical structure or a component in modules like SAP PM (Plant Maintenance), SAP PS (Project System), or SAP PP (Production Planning), where breakdowns or structures are maintained.

    Common causes include:

    • The breakdown ID does not exist or was deleted.
    • The breakdown ID was never created or incorrectly referenced.
    • Data inconsistency or missing master data.
    • Incorrect or outdated references in custom code, user exits, or reports.
    • Transport or system copy issues where the breakdown data was not moved properly.

    Solution / How to Fix:

    1. Verify the Breakdown ID:

      • Check the exact breakdown ID mentioned in the error message.
      • Use transaction codes relevant to the module to search for the breakdown:
        • For PM: Use IL03 (Display Functional Location) or IW33 (Display Notification) if related.
        • For PS: Use CJ20N (Project Builder) or CN41 (Structure Overview).
        • For PP or other modules, use the relevant transaction to check the breakdown or structure.
    2. Check Master Data:

      • Confirm that the breakdown exists in the system.
      • If missing, create the breakdown or correct the reference.
    3. Check Custom Code or User Exits:

      • If the error occurs during a custom program or enhancement, debug to see where the breakdown ID is fetched.
      • Ensure the code handles cases where the breakdown might not exist.
    4. Data Consistency Check:

      • Run consistency reports or database checks for the relevant module.
      • For example, in PM, use IW28 or IW29 to list notifications and check for inconsistencies.
    5. Transport and System Copy:

      • If the error appeared after a transport or system copy, verify that all relevant master data was transported correctly.
      • Re-transport missing data if necessary.
    6. SAP Notes and Support:

      • Search SAP Support Portal for notes related to WXP679.
      • Sometimes, specific patches or corrections are available.

    Additional Information:

    • The message class WXP is often related to Workflow or PM/PS breakdown structures.
    • The placeholder &1 will be replaced by the actual breakdown ID in the error message.
    • This error is a warning or error indicating missing data, which can halt processing or workflow steps.
    • Always ensure that the breakdown structures are maintained properly in master data to avoid such errors.

    Summary:

    Aspect Details
    Error WXP679 Break-down &1 does not exist in system
    Cause Referenced breakdown ID missing or deleted in the system
    Solution Verify and create/fix breakdown master data; check custom code; ensure data consistency
    Related Areas SAP PM, PS, PP modules; Workflow; Master data maintenance
    Transactions IL03, IW33, CJ20N, CN41, IW28, IW29 (depending on module)

    If you provide the exact module or context where this error occurs, I can give more targeted advice.

    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Sign up for our Free Essentials Plan.


Related SAP Error Messages

Click the links below to see the following related messages:

Click on this link to search all SAP messages.


Rating
The AI Support Assistant is great. It provides comprehensive assistance even on the most difficult issues. I highly recommend this service.
Rate 1
John Jordan
SAP Consultant & Author