Message type: E = Error
Message class: WXP - Retail Planning
Message number: 604
Message text: A maximum of two characteristics can be assigned to interface &1
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
INCLUDE WISP_PLINT_DIMENSIONS OBJECT DOKU ID TXError message extract from SAP system. Copyright SAP SE.
WXP604
- A maximum of two characteristics can be assigned to interface &1 ?SAP Error Message: WXP604 - A maximum of two characteristics can be assigned to interface &1
Cause: This warning message occurs in SAP when you try to assign more than two characteristics to a classification interface. According to SAP's design and system restrictions, an interface can have at most two characteristics assigned to it. Attempting to assign a third characteristic violates this rule, triggering the WXP604 warning. Explanation: Classification Interface: In SAP, interfaces are used to group characteristics for classification purposes, often in the context of variant configuration or classification. Restriction: SAP limits the number of characteristics per interface to two to maintain system performance and consistency in classification logic. When you try to assign a third characteristic to the same interface, the system issues this warning to prevent the assignment.
Solution: Review the characteristics assigned to the interface: Check which two characteristics are already assigned. Remove or reassign characteristics: If possible, remove one of the existing characteristics from
Get instant SAP help. Sign up for our Free Essentials Plan.
WXP603
Errors/warnings have occurred. Read the log ...
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
WXP602
Assign an interface for promotions to layout &3
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
WXP605
A maximum of two break-downs can be assigned to interface &1
What causes this issue? The system issues an error message and will not allow you to continue with this transaction until the error is resolved. INC...
WXP606
No extra break-downs can be assigned to interface &1
What causes this issue? The combination of characteristics and break-downs you have entered is not recognized.System Response The system issues an e...
Click on this link to search all SAP messages.