How To Fix V1707 - Maintain table TNAPR for output &1, type &2, application &3


SAP Error Message - Details

  • Message type: E = Error

  • Message class: V1 - Verkaufsbelegbearbeitung

  • Message number: 707

  • Message text: Maintain table TNAPR for output &1, type &2, application &3

  • Show details Hide details


  • Self-Explanatory Message

    Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.

    To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.

    Unfortunately, there isn't any extra information in this error notice.



    What else can you do?

    First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).

    Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.

    You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.


Smart SAP Assistant

  • What is the cause and solution for SAP error message V1707 - Maintain table TNAPR for output &1, type &2, application &3 ?

    The SAP error message V1707 indicates that there is an issue with the output determination configuration in the system. Specifically, it suggests that the system is unable to find the necessary entries in the TNAPR table for the specified output type, application, and other parameters.

    Cause:

    The error typically arises due to one of the following reasons:

    1. Missing Entries in TNAPR Table: The TNAPR table, which is used for output determination, does not have the required entries for the specified output type and application.
    2. Incorrect Configuration: The output type or application may not be correctly configured in the system.
    3. Transport Issues: If the configuration was recently transported from another system, it may not have been transported correctly, leading to missing entries.

    Solution:

    To resolve the V1707 error, you can follow these steps:

    1. Check TNAPR Table:

      • Go to transaction SE16 or SE16N and enter the table name TNAPR.
      • Check if there are entries for the specified output type, application, and other parameters mentioned in the error message.
    2. Maintain TNAPR Entries:

      • If the required entries are missing, you can create them using transaction NACE.
      • Navigate to the relevant application area (e.g., Sales, Purchasing) and select the output type.
      • Ensure that the output type is correctly configured and that the necessary conditions are set.
    3. Review Output Type Configuration:

      • In transaction NACE, check the configuration for the output type to ensure it is set up correctly.
      • Verify that the output type is assigned to the correct application and that the necessary conditions are defined.
    4. Transport Issues:

      • If the configuration was recently transported, check the transport logs to ensure that all necessary objects were included in the transport request.
      • If needed, re-transport the configuration or manually create the missing entries.
    5. Testing:

      • After making the necessary changes, test the output determination process to ensure that the error no longer occurs.

    Related Information:

    • Transaction Codes:
      • NACE: Output Types Configuration
      • SE16/SE16N: Table Display
    • Documentation: Refer to SAP Help documentation for detailed information on output determination and configuration.
    • Support: If the issue persists after following the above steps, consider reaching out to SAP support or consulting with a functional consultant who specializes in the relevant module (e.g., SD, MM).

    By following these steps, you should be able to resolve the V1707 error and ensure that the output determination process works correctly in your SAP system.

    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Sign up for our Free Essentials Plan.


Related SAP Error Messages

Click the links below to see the following related messages:

Click on this link to search all SAP messages.


Rating
The AI Support Assistant is great. It provides comprehensive assistance even on the most difficult issues. I highly recommend this service.
Rate 1
John Jordan
SAP Consultant & Author