Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: UCF4 - Messages on Reclassification
Message number: 107
Message text: Method &1: Trigger: Target item &2 is not permitted as the trigger
In step &V3& of reclassification method &V1&, you use item &V2& in the
trigger definition. You also specified this item as the target
assignment.
You have assigned reclassification method &V1& to reclassification task
&V4&. In this task, you have selected the <LS>Assets Held for Sale</>
checkbox, but you have <ZH>not</> selected the <LS>Valuation Allowance
of Assets/Liabilities</> checkbox.
For this type of task, the target assignment of the reclassification
method is the <LS>Assets Held for Sale</>, <LS>Liabilities Held for Sale
</>, or <LS>Discontinued Operations</> item. You <ZH>cannot</> use this
target assignment in the trigger for the reclassification method.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Adjust the Customizing settings for the trigger in reclassification
method &V1& as described above by removing item &V2& from the trigger
selection.
Error message extract from SAP system. Copyright SAP SE.
UCF4107
- Method &1: Trigger: Target item &2 is not permitted as the trigger ?The SAP error message UCF4107 typically occurs in the context of the SAP Convergent Charging (SAP CC) application. This error indicates that there is an issue with the configuration of a trigger in a charging scenario. Specifically, it means that the target item specified in the trigger is not allowed or is not valid for the operation being performed.
Cause:
The error can be caused by several factors, including:
Invalid Configuration: The target item specified in the trigger may not be configured correctly in the system. This could be due to missing or incorrect settings in the charging configuration.
Business Rules: The business rules defined for the charging scenario may not allow the specified target item to be used as a trigger. This could be due to restrictions based on the type of item or the context in which it is being used.
Data Integrity Issues: There may be issues with the data integrity of the items involved, such as missing dependencies or relationships that are required for the trigger to function properly.
Version Compatibility: If there have been recent updates or changes to the SAP CC system, there may be compatibility issues with existing configurations.
Solution:
To resolve the UCF4107 error, you can take the following steps:
Check Configuration: Review the configuration of the trigger and ensure that the target item is correctly defined. Verify that all necessary parameters and settings are in place.
Review Business Rules: Examine the business rules associated with the charging scenario to ensure that the target item is permitted as a trigger. If necessary, modify the rules to allow the use of the target item.
Data Validation: Validate the data integrity of the items involved in the trigger. Ensure that all required relationships and dependencies are correctly established.
Consult Documentation: Refer to the SAP documentation for Convergent Charging to understand the specific requirements and limitations regarding triggers and target items.
Testing: After making changes, conduct thorough testing to ensure that the trigger works as expected and that the error does not reoccur.
Seek Support: If the issue persists, consider reaching out to SAP support or consulting with an SAP expert who specializes in Convergent Charging for further assistance.
Related Information:
By following these steps, you should be able to identify the root cause of the UCF4107 error and implement an appropriate solution.
Get instant SAP help. Sign up for our Free Essentials Plan.
UCF4106
Method &1: Trigger: Obsolete selection of consolidation unit or partner
What causes this issue? In step &V2& of reclassification method &V1&, you have specified a selection of consolidation units, partner ...
UCF4105
Method &1: Trigger: Incorrect use of document type &2
What causes this issue? In step &V3& of reclassification method &V1&, you have specified document type &V2& in the trigger. Y...
UCF4108
Method &1: Target assignment &2 is not unique for all steps
What causes this issue? In step &V3& of reclassification method &V1&, you have specified item &V2& as the target assignment. ...
UCF4109
Method &1: Source assignment &2 is not unique for all steps
What causes this issue? In step &V3& of reclassification method &V1&, you have specified item &V2& as the source assignment. ...
Click on this link to search all SAP messages.